9.2 Filter Option
In countries where noise across power lines is a concern,
Mold-Masters
recommends that an inline filter is fitted. Please contact
Mold-Masters
for
details.
9.3 Alarm Output / Auxiliary Input
An optional cabinet connector provides an alarm output from an internal set
of relay contacts. Using an external power source, the cabinet can initiate
a number of warning devices whenever any zone goes into an alarm state.
This is commonly used for beacons, audible alarms or informing the molding
machine. In order to capture fleeting alarm conditions, the relay is held on for
about 15 seconds after the alarm condition is cleared. The contacts are rated
for 5A at 240V.
Table 9-1 Alarm Output / Auxiliary Input
Pin
Connection
Input / Output
1
Auxiliary Input signal
Standby
2
Auxiliary Input ground
3
Alarm 240v contact 1
Normally Open Contacts
4
Alarm 240v contact 2
An optional input can be accepted through the same connector. It may be
used for Cycle Synch spear tips, Inhibit mode, remote Boost / Standby or any
other user-definable function. For exact details, consult the specification for
your particular model.
9.4 USB Port
A USB port is provided which enables certain functions such as:
• backup and restore tool settings
• save tool test results
• printer output
Table 9-2 Pin Connections
Pin
Connection
1
VCC
2
D-
3
D+
4
GND
Figure 9-5 USB port
9-4
M1 Plus Controller User Manual
HOT RUNNER CONTROLLER WIRING DETAILS
© 2021 Mold-Masters (2007) Limited. All Rights Reserved.