19
10. ISSUE SOLVING AND TECHNICAL DATA
Issues
Error
Possible reason
Solution
Mobeye MS100BK cannot be
switched on. You hear an error
tone, the red light is turned on
shortly.
No valid Telephone number was
entered.
Enter a valid number.
The light is flashing red during
switching on.
No valid SIM card was entered
or the SIM card was not made
pin code free.
Check the SIM card.
It is impossible to change the
settings. After entering your
personal code, followed by menu,
the error tone is played and the
light turns red.
Mobeye is activated.
Switch off the Mobeye
MS100BK.
No GSM signal during the GSM
test
No network is available,
belonging to the SIM cards
provider.
Choose another network
provider.
The light remains red.
You entered an incorrect
installation or user code three
times.
Wait 10 minutes and then
re-enter the correct
installation or user code.
You do not receive an SMS with
the settings.
Telephone number is not
correct.
Re-program the telephone
number
at position ‘01’
For other questions, please refer to the site www.mobeye.eu
Technical data
• GSM: Quad Band EGSM 850/900/1800/1900 MHz
compatible to the ETSI GSM Phase 2+ standard
• Temperature range: -10°C until +55°C
• Dimensions: 161 x 90 x 35 mm (LxWxH)
• Batteries: 4 x CR123 Lithium 3.0 V
• Power, battery operated: 50 μA, short peaks of max. 2 A
• Power, ext. powered: 50 mA, short peaks of max. 2 A
For support on technical problems regarding Mobeye MS100BK please contact
[email protected].