17 

CODE COMMAND:OPTION 

CODE 

COMMAND

:

OPTION

#

COMMAND

:

OPTION

#

COMMAND

:

OPTION

 

Setting 

 

Menu/ 
command 

Options 

Factory 
default 

TEL4 

Keypad 

104 

Telephone number 

 

SMS 

TEL4: 

TEL5 

Keypad 

105 

Telephone number 

 

SMS 

TEL5: 

Delete telephone 
number 

Keypad 

101…105 

 

SMS 

DEL1….DEL5 

 

Authorise telephone 
number 

Keypad 

201…250 

Tel. number 

 

SMS 

TELA1: ...TELA50: 
of ADDTELA: 

Delete authorised 
number 

Keypad 

201…250 

 

SMS 

DELA:1..DELA:50   

Authorised remote 
control 

Keypad 

90 

ON, OFF 

ON 

SMS 

AUTH: 

Identification text 

Keypad 

 

 

SMS 

NAME: 

20 characters 

Mobeye 

Alarm text power 
failure 

Keypad 

 

 

SMS 

TEXT2: 

20 characters 

Power 
failure 

Alarm text power 
restored 

Keypad 

 

 

SMS 

TEXT3: 

20 characters 

Power 
restored 

Alarm text input 1 

Keypad 

 

 

SMS 

TEXT4: 

20 characters 

Alarm 1 

Alarm text input 2 

Keypad 

 

 

SMS 

TEXT5: 

20 characters 

Alarm 2 

Text restored input 1 

Keypad 

 

 

SMS 

TEXT6: 

20 characters 

Input 1 
restored 2 

Text restored input 2 

Keypad 

 

 

SMS 

TEXT7: 

20 characters 

Input 2 
restored 

 

Program method using the keypad: 

 
CODE    

menu

    menu nr.    OK     option   OK 

 
Program method via SMS (in program mode): 
 

 
 
Or several commands at once: 
 

 
 

Leave the menu 

The menu can be left from any position, by pressing “OK” twice.  

 

Summary of Contents for MS100BK

Page 1: ...Installation manual Mobeye MS100BK GSM Measure Control and Alarm module SW version 7 n...

Page 2: ......

Page 3: ...F 10 6 6 Interval test message 10 6 7 Set actual time and date 10 6 8 Automatic time based arm disarm 11 6 9 identification text 11 6 10 Alarm text 11 6 11 Input type 11 6 12 Input delay time 11 6 13...

Page 4: ...nded for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflamma...

Page 5: ...ing the text such as Mobeye Input 1 OK or Mobeye Input 2 OK If the sensor and or the input remain in the alarm status the Mobeye MS100BK repeats sending the SMS alarm message every four hours With jus...

Page 6: ...he back cover Insert the SIM card in the holder For opening closing move the cover slightly 2 2 CONNECT A SENSOR Open the hole in the enclosure and insert the 2 wires of an external sensor through the...

Page 7: ...10027 The black wire with the white line is the other black wire is Close the Mobeye MS100BK using the 4 screws 2 5 PROGRAM THE PHONE NUMBERS You need to program at least one phone number in the unit...

Page 8: ...ablish a connection to the network First an SMS text message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm usi...

Page 9: ...o remotely control the system Please find below the architecture of the main unit Inputs External sensors can be connected to the inputs Upon closing or opening an input the Mobeye MS100BK will send a...

Page 10: ...To program a telephone number at memory position 2 1111 MENU 102 OK 004934578692 OK To set the SMS to OFF just call 1111 MENU 12 OK 0 OK 5 2 CONFIGURATION VIA SMS TEXT MESSAGES Almost all options can...

Page 11: ...th SMS commands is listed chapter 8 The commands are case sensitive Several commands may be combined in one SMS message with a maximum of 160 characters by placing a between the commands A confirmatio...

Page 12: ...OFF By default the Mobeye MS100BK sends alarm notifications via text message and calls to the preset contact persons By turning off the SMS the unit will only call after the sensors send an alarm 6 5...

Page 13: ...an input is set to NO the alarm will be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered if the connection between the input terminals is bro...

Page 14: ...them be switched by any incoming call SMS without being authorised To disable the need for authorised numbers the authorization option can be set to OFF Default is ON 6 17 DURATION OF OUTPUTS SWITCH...

Page 15: ...puts 2 Power failure Send SMS call 3 Power restored Send SMS 4 Input 1 triggered Send SMS call 5 Input 2 triggered Send SMS call 6 Input 1 restored Send SMS 7 Input 2 restored Send SMS The SMS texts a...

Page 16: ...ION1 REACTION2 REACTION3 Do not forget the space between CODE and the TRIGGER The Mobeye MS100BK will play a short melody to indicate a successful configuration In case of a wrong command a long beep...

Page 17: ...uence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its index number even if a rule with a previous number is deleted This will result in gap...

Page 18: ...pad 71 0 off 1 NO 2 NC 1 NO SMS TYPEIN1 OFF NO NC Input type input 2 Keypad 72 0 off 1 NO 2 NC 1 NO SMS TYPEIN2 OFF NO NC Inactive time Input 1 Keypad 73 0 999 min 5 SMS INACTIVEINP1 Inactive time inp...

Page 19: ...tification text Keypad SMS NAME 20 characters Mobeye Alarm text power failure Keypad SMS TEXT2 20 characters Power failure Alarm text power restored Keypad SMS TEXT3 20 characters Power restored Alarm...

Page 20: ...EST GSM NETWORK STRENGTH Before using the Mobeye MS100BK is it advised to test the GSM signal strength at the location Enter the installation code Press menu Press 512 Press OK The Mobeye MS100BK will...

Page 21: ...available belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes and then re enter th...

Page 22: ...2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low volta...

Page 23: ......

Reviews: