6.8 AUTOMATIC TIME-BASED ARM/DISARM 

The  MS100BK  can  be  armed  and/or  disarmed  based  on  a  daily  time  schedule.  The  first 
telephone number needs to be set before the arming and/or disarming time can be set.  

6.9 IDENTIFICATION TEXT 

It  is  possible  to  add  a  standard  identification  text  (NAME)  to  all  messages  sent  out  by  the 
Mobeye MS100BK. The alarm messages are a combination of the name and the alarm text. 
A  user  defined  identification  has  a  length  of  maximum  20  characters.  The  default 
identification text is ‘Mobeye’. 
The identification text cannot be changed by keypad, just by SMS command. 

6.10 ALARM TEXT 

Custom  alarm  texts  can  be  programmed.  These  texts  have  a  maximum  length  of  20 
characters.  
The following texts are programmed as factory default: 
 
Power failure    

TEXT2: power failure 

Power restored 

TEXT3: power restored 

Triggered input 1 

TEXT4: alarm 1 

Triggered input 2  

TEXT5: alarm 2 

Restored input 1 

TEXT6: Input 1 restored 

Restored input 2 

TEXT7: Input 2 restored 

 
The alarm text cannot be changed by keypad, just by SMS command. 

6.11 INPUT TYPE 

The input type defines the character of the inputs IN1 and IN2. This can be Normally  Open 
(NO) or Normally Closed (NC). If an input is set to NO, the alarm will be triggered as soon as 
the  terminals  of  the  input  are  closed.  If  the  input  is  set  to  NC,  the  alarm  is  triggered  if  the 
connection between the input terminals is broken.  
The default input type is set to NO. 

6.12 INPUT DELAY TIME 

The  input  delay  time  defines  the  time  that  the  inputs  are  triggered  before  an  alarm  is 
initiated. If the input returns to the non-alarm status within the delay time, no alarm is sent. 
The delay time can be set between 0 and 999 seconds. 
As default, the input delay time is set to 1 second. 

6.13 INACTIVE TIME 

The  “inactive  time”  defines  the  time  the  movement  sensor,  input  1  or  input  2  is  not  active 
after  an  acti

vation.  If  the  time  is  set  to  “0” (minutes),  the  input  is  active  again  immediately 

after returning to the non-alarm status. If the time is set to e.g. 30 minutes, the input remains 
inactive for the first 30 minutes. If the input is again (or still) activated after these 30 minutes, 
a new alarm message is sent. The inactive time can be set between 0 and 60 minutes.  
As default, the inactive time is set to “5” for all inputs. 

6.14 POWER FAILURE DELAY TIME 

The power failure delay time defines the time that the power fails before an alarm is initiated. 
If  the  power  is  restored  within  the  delay  time,  no  alarm  is  sent.  The  delay  time  can  be  set 
between 0 and 60 minutes. As default, the delay time is set to 1. 

Summary of Contents for MS100BK

Page 1: ...Installation manual Mobeye MS100BK GSM Measure Control and Alarm module SW version 7 n...

Page 2: ......

Page 3: ...F 10 6 6 Interval test message 10 6 7 Set actual time and date 10 6 8 Automatic time based arm disarm 11 6 9 identification text 11 6 10 Alarm text 11 6 11 Input type 11 6 12 Input delay time 11 6 13...

Page 4: ...nded for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflamma...

Page 5: ...ing the text such as Mobeye Input 1 OK or Mobeye Input 2 OK If the sensor and or the input remain in the alarm status the Mobeye MS100BK repeats sending the SMS alarm message every four hours With jus...

Page 6: ...he back cover Insert the SIM card in the holder For opening closing move the cover slightly 2 2 CONNECT A SENSOR Open the hole in the enclosure and insert the 2 wires of an external sensor through the...

Page 7: ...10027 The black wire with the white line is the other black wire is Close the Mobeye MS100BK using the 4 screws 2 5 PROGRAM THE PHONE NUMBERS You need to program at least one phone number in the unit...

Page 8: ...ablish a connection to the network First an SMS text message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm usi...

Page 9: ...o remotely control the system Please find below the architecture of the main unit Inputs External sensors can be connected to the inputs Upon closing or opening an input the Mobeye MS100BK will send a...

Page 10: ...To program a telephone number at memory position 2 1111 MENU 102 OK 004934578692 OK To set the SMS to OFF just call 1111 MENU 12 OK 0 OK 5 2 CONFIGURATION VIA SMS TEXT MESSAGES Almost all options can...

Page 11: ...th SMS commands is listed chapter 8 The commands are case sensitive Several commands may be combined in one SMS message with a maximum of 160 characters by placing a between the commands A confirmatio...

Page 12: ...OFF By default the Mobeye MS100BK sends alarm notifications via text message and calls to the preset contact persons By turning off the SMS the unit will only call after the sensors send an alarm 6 5...

Page 13: ...an input is set to NO the alarm will be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered if the connection between the input terminals is bro...

Page 14: ...them be switched by any incoming call SMS without being authorised To disable the need for authorised numbers the authorization option can be set to OFF Default is ON 6 17 DURATION OF OUTPUTS SWITCH...

Page 15: ...puts 2 Power failure Send SMS call 3 Power restored Send SMS 4 Input 1 triggered Send SMS call 5 Input 2 triggered Send SMS call 6 Input 1 restored Send SMS 7 Input 2 restored Send SMS The SMS texts a...

Page 16: ...ION1 REACTION2 REACTION3 Do not forget the space between CODE and the TRIGGER The Mobeye MS100BK will play a short melody to indicate a successful configuration In case of a wrong command a long beep...

Page 17: ...uence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its index number even if a rule with a previous number is deleted This will result in gap...

Page 18: ...pad 71 0 off 1 NO 2 NC 1 NO SMS TYPEIN1 OFF NO NC Input type input 2 Keypad 72 0 off 1 NO 2 NC 1 NO SMS TYPEIN2 OFF NO NC Inactive time Input 1 Keypad 73 0 999 min 5 SMS INACTIVEINP1 Inactive time inp...

Page 19: ...tification text Keypad SMS NAME 20 characters Mobeye Alarm text power failure Keypad SMS TEXT2 20 characters Power failure Alarm text power restored Keypad SMS TEXT3 20 characters Power restored Alarm...

Page 20: ...EST GSM NETWORK STRENGTH Before using the Mobeye MS100BK is it advised to test the GSM signal strength at the location Enter the installation code Press menu Press 512 Press OK The Mobeye MS100BK will...

Page 21: ...available belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes and then re enter th...

Page 22: ...2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low volta...

Page 23: ......

Reviews: