MK-370
Revision 06/05, Effective Date June 17, 2005
Page 29
MAINTENANCE AND TROUBLESHOOTING
4. Blade Stops Turning:
(D)
Verify the circuit breaker is at
least 20 amps – if not, move to
20-amp circuit
(C)
Check to see if the Ground
Fault Circuit Interrupter (GFCI)
tripped
(G)
Return to MK Diamond
Return to
MK Diamond
for Repair
(A)
Check the ON/OFF Switch is in
the ON position
If switch is on
go to Step B
If connected
go to Step C
If not tripped or
if re-trip occurs,
go to Step D
Reset once
if tripped
(B)
Verify all plugs are fully
connected
If less than 20
Amps move saw
to 20 Amp circuit
If circuit 20 Amp
or greater go to
Step E
Check Breaker
20 Amps or
greater
(E)
Verify circuit breaker not
tripped; if it is tripped, reset it
once only
If tripped, reset
once, if it trips
again, go to step F
If circuit breaker
not tripped go to
Step F
Check Breaker
tripped
(F)
Check power source voltage is
115V – if not 115v, move to
another circuit
If voltage is
correct, go
to Step F
Check for
correct circuit
voltage
Verify all plugs
connected
ON
Position