![Miyachi Unitek ISA Series Operator'S Manual Download Page 99](http://html1.mh-extra.com/html/miyachi-unitek/isa-series/isa-series_operators-manual_1812774099.webp)
APPENDIX F: COMMUNICATIONS
ISA-4001CR INVERTER POWER SUPPLY
990-364
F-5
Host Originated Command Set
These are commands sent by the host computer, via the RS-485 port to the ISA.
NAME COMMAND
DATA
SIZE
TYPE
“TY” Read
none
0 Bytes
STATUS
“TA” Read
none
1 Bytes
CONTROL#
“CN” Read
none
0 Bytes
COUNT
“CT” Read
Returns # reports stored
0 Bytes
REPORT
“RR” Read
Request # (1-8 or Retransmission = 0x0FF)
1 Byte
RESET
“RX” Set
Reset an Error and Returns STATUS
0 Bytes
REMOTE
“RM” Set
0=Local, 1=Remote (After Ver. 1.01 B)
1 Byte
LOAD
“LR” Read
none
0 Bytes
“LS” Set
0=Hardware Select, 1-64= Selects
1 Byte
active schedule.
NOTE:
Before Ver. 1.02C this was set through hardware only.
COPY
“CP” Set
Source schedule #,
1 Byte
Destination schedule #.
1 Byte
Count past
1 Byte
3 Bytes Total
TIME CLK
“RT” Set
<data>=0 Reset time clock
Read
<data>=1 Read time offset
1 Byte
LINK
“KR” Read
0=Chaining, 1=Successive
1 Byte
“KS” Set
0=Chaining, 1=Successive
1 Byte
Number of Schedules (n)
1 Byte
SCHEDULE #, SCHEDULE #, ...
n Bytes
Summary of Contents for ISA Series
Page 16: ...CHAPTER 1 SYSTEM DESCRIPTION ISA 4001CR INVERTER POWER SUPPLY 1 4 990 364 ...
Page 22: ......
Page 30: ......
Page 44: ......
Page 48: ......
Page 62: ......
Page 76: ......
Page 87: ...APPENDIX C SYSTEM TIMING ISA 4001CR INVERTER POWER SUPPLY 990 364 C 11 Pulsation Pulsation ...
Page 108: ......
Page 112: ......
Page 114: ......
Page 116: ......
Page 118: ......