CHAPTER 3: USING ISA SERIES PROGRAMMING FUNCTIONS
ISA-4001CR INVERTER POWER SUPPLY
3
-2
990-364
Power Supply State Screen
This screen is used to set and display the
information on the Power Supply.
CONTROL #
--
This is used to enter the
identification number of the Power
Supply. This is an arbitrary number for
your records and can be up to four digits
long.
POWER SUPPLY STATE
CONTROL #
1234
PROGRAMMED
DATE 1998.09.14
WELD
POWER
FREQUENCY
1000Hz
MA-627A
ROM
VERSION
#
[V01-01A]
ISA-4000A ROM VERSION #[V01-01A]
NOTE:
If
WeldLab
software is being used with the Power Supply, the first 2 digits of the control
number are used as the unit 485 address. Therefore, those 2 digits must be set to 01 through 30 to
communicate properly with WeldLab.
PROGRAMMED DATE
– This is used for entering the date when the data is being entered. The date is
entered in year/month/date form, separated by periods
MA-627A ROM VERSION #
– This is the ROM version of the program loaded in the Program Unit.
ISA-500A/ISA-1000/ISA-2000 ROM VERSION
– This is the ROM version of the program loaded in the
Power Supply.
POWER SOURCE FREQUENCY
– The frequency of the line power is automatically measured and
indicated.
WELD POWER FREQUENCY
– The factory setting for output frequency is 1000Hz. This can be
switched by changing the settings on dipswitch
SW3
on the motherboard. There are 3 options:
x
600 Hz
x
800Hz
x
1000 Hz
Instructions are in
Appendix G, Dipswitch Settings.
Schedule Screens
Up to 64 welding schedules can be set on the Power Supply, indicated
as
#001
through
#064
. The screen
is used to set the schedule number, length of weld time, welding current, etc. The data is the same for
all ten modes, as shown. To switch from the ms mode to the cycle (CYC) mode, go to the Mode Select
screen (selected from the Main screen), and select
CYCLE WELD ON
.
CYCLE WELD OFF
will change the
mode back to the ms mode.
NOTE:
Use the
keys to select the data field, then use the +/- keys or the keypad to enter numbers.
Primary Constant-Current
Effective Value Control –
ms Mode
NOTE:
Minimum heat values on the
ISA-2000 screen are 08.0 kA, maximum
values are 160.0kA.
SCHEDULE # 001
CTRL 0
< PRIMARY RMS>
SQD
SQZ WE1
COOL
WE2
HOLD
OFF
TIME
0000
0000
000 000 000 000 0000ms
UP SLOPE
000
000
ms
DOWN SLOPE
000
000
ms
HEAT
32.0
32.0
kA
PULSATION 1
GAIN
(1-9)
1
PAGE DOWN
WELD
ON/OFF
OFF
SCHEDULE #
–
This entry is used to designate the Schedule number,
001
through
064
.
Summary of Contents for ISA Series
Page 16: ...CHAPTER 1 SYSTEM DESCRIPTION ISA 4001CR INVERTER POWER SUPPLY 1 4 990 364 ...
Page 22: ......
Page 30: ......
Page 44: ......
Page 48: ......
Page 62: ......
Page 76: ......
Page 87: ...APPENDIX C SYSTEM TIMING ISA 4001CR INVERTER POWER SUPPLY 990 364 C 11 Pulsation Pulsation ...
Page 108: ......
Page 112: ......
Page 114: ......
Page 116: ......
Page 118: ......