APPENDIX F: COMMUNICATIONS
ISA-4001CR INVERTER POWER SUPPLY
F-8
990-364
NAME COMMAND
DATA
SIZE
STEPPER
“GR” Read
Valve #
1 Byte
STEPPER
“GS” Set
VALVE #,
1 Byte
START ON STEP #,
1 Byte
STEP 1 COUNT #,
(0-9999)
2 Bytes
STEP 2 COUNT #,
2 Bytes
STEP 3 COUNT #,
2 Bytes
STEP 4 COUNT #,
2 Bytes
STEP 5 COUNT #,
2 Bytes
STEP 6 COUNT #,
2 Bytes
STEP 7 COUNT #,
2 Bytes
STEP 8 COUNT #,
2 Bytes
STEP 9 COUNT #,
2 Bytes
STEP %
“FR” Read
Schedule #
1 Byte
STEP %
“FS” Set
Schedule #
1 Byte
(Added after V1.01 B)
STEP 1 % #,
(50% - 200%)
1 Byte
STEP 2 % #,
1 Byte
STEP 3 % #,
1 Byte
STEP 4 % #,
1 Byte
STEP 5 % #,
1 Byte
STEP 6 % #,
1 Byte
STEP 7 % #,
1 Byte
STEP 8 % #,
1 Byte
STEP 9 % #,
1 Byte
(Added after V1.01 B)
Tip Dress Step 1,
[0000 000x]
1 Bit
Tip Dress Step 2,
[0000 00x0]
1 Bit
Tip Dress Step 3,
[0000 0x00]
1 Bit
Tip Dress Step 4,
[0000 x000]
1 Bit
Tip Dress Step 5,
[000x 0000]
1 Bit
Tip Dress Step 6,
[00x0 0000]
1 Bit
1 Byte
Tip Dress Step 7,
[0000 000x]
1 Bit
Tip Dress Step 8,
[0000 00x0]
1 Bit
Tip Dress Step 9,
[0000 0x00]
1 Bit
Tip Dress Step 10,
[0000 x000]
1 Bit
1 Byte
Tip
Dress
Value,
(0-99)
2
Bytes
Cap
Change,
(0-9999)
2
Bytes
16 Bytes Total
Summary of Contents for ISA Series
Page 16: ...CHAPTER 1 SYSTEM DESCRIPTION ISA 4001CR INVERTER POWER SUPPLY 1 4 990 364 ...
Page 22: ......
Page 30: ......
Page 44: ......
Page 48: ......
Page 62: ......
Page 76: ......
Page 87: ...APPENDIX C SYSTEM TIMING ISA 4001CR INVERTER POWER SUPPLY 990 364 C 11 Pulsation Pulsation ...
Page 108: ......
Page 112: ......
Page 114: ......
Page 116: ......
Page 118: ......