APPENDIX G: DIPSWITCH SETTINGS
ISA-4001CR INVERTER POWER SUPPLY
G-2
990-364
WARNING
Never
attempt to change dipswitch settings while power is ON
or
when the
capacitors are charged. You may receive an electric shock.
Before
setting the
dipswitch, perform the pre-maintenance shutdown procedures described in
Chapter 4, Maintenance
.
Weld Power Frequency [SW3]
CAUTION:
Do
not
change the settings on
switch positions 6-8.
You have three weld output power frequency
options as shown on the right:
x
600 Hz
x
800Hz
x
1000 Hz
NOTE:
The factory setting is 1000Hz.
Stepper Settings [SW4]
CAUTION:
Do
not
change the settings on
switch positions 1-2 or 4-8.
Use switch position
3
to switch between
LINEAR STEPPER
and
NON-LINEAR STEPPER
as shown on the right.