![Mitsubishi ST200 Series Technical Support Manual Download Page 67](http://html1.mh-extra.com/html/mitsubishi/st200-series/st200-series_technical-support-manual_1808680067.webp)
MITSUBISHI ELECTRONICS AMERICA, INC.
ST200 Series Technical Support Manual
64
January 2000
During Steps 4 and 5, if there is a code already used and stored in the memory, it will appear at
this time. If this code is correct, press STO/END to proceed to the next step without re-entry of
the code.
If you enter the wrong digits and then press STO/END, the MT may not proceed to the next step.
If this happens, re-enter the code. To return to the previous step, press the CLR key.
6. Press SEND for at least ½ second to start the Pilot/GC-S acquisition process.
6a. The MT will then prompt you to conduct the manual pointing setup procedure with the
following message.
After confirming the Beam ID and maximizing the Received Signal Strength indication,
press the | * | key to start the GC-S selection. To return to step 4, press the | # | key twice.
7. During acquisition, the following message is shown if the Status Monitor is OFF (for a
list of messages with Status Monitor ON see Appendix A).
If you want to suspend manual selection while SAT Search is displayed, press STO/END for at
least ½ second to make the MT reset.
8. The result of Manual Pilot/GC-S Selection is indicated on the display as follows:
Successful Manual GC-S selection:
−
The MT proceeds to the next step (Commissioning or Log-on) automatically.
Failed Pilot selection :
−
Re-enter the PFC, then press STO/END (this is the same as step 4).
Failed GC-S selection :
CFC=XXX
XXXXXX
PFC=XXX
XXXXXX
SAT
-ON-
SAT
Search
To Srch
PushSND
BnnSmm
OK*/NG