96
-
(d)
Explain to the customer on the correct usage of the air conditioner in simple layman’s terms.
(e)
Make sure that drain flows properly.
(f)
Standard operation data
Model
Item
SRK22ZEV-S
Cooling
–
Heating
2.5~2.7
Cooling
0.8~1.0
Heating
–
Cooling
12~14
Heating
16~18
Cooling
8.4
Running current (A)
Heating
8.5
Low pressure (MPa)
Temp. difference between
return air and supply air (
°
C)
High pressure (MPa)
(220V)
Note (1) The data are measured at following conditions
Ambient air temperature
Indoor side: Cooling ... 27˚C DB, 19˚C WB, Heating ... 20˚C DB
Outdoor side: Cooling ... 35˚C DB, 24˚C WB, Heating ... 7˚C DB, 6˚C WB
0
0.2
0.4
0.6
0.8
1
1.2
1.4
15
20
25
30
35
40
45
50
C
A
P
A
C
ITY
R
A
TI
O
Hi
Me
Lo
ULo
Rated
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
- 15
- 10
- 5
0
5
10
15
20
25
CA
P
A
CI
T
Y
R
A
T
IO
Hi
Me
Lo
ULo
HEATING CHARACTORISTICS
COOLING CHARACTARISTICS
INDOOR CONDITION: DB20
°
C
OUTDOOR DB TEMP.(
°
C)
INDOOR CONDITION: DB27
°
C/WB19
°
C
OUTDOOR DB TEMP.(
°
C)
Summary of Contents for SRK10CES
Page 2: ...TECHNICAL MANUAL...
Page 204: ...202 MEMO...
Page 213: ...211...
Page 227: ...225...
Page 233: ...231...
Page 236: ...CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY 234...
Page 244: ...CRBE0228 9 15 7 8 1 2 4 5 6 12 13 14 10 11 3 PANEL FAN ASSY 242...
Page 248: ...CRBE0227 11 15 16 1 2 3 5 6 7 8 9 12 13 14 4 10 PANEL FAN ASSY 246...
Page 252: ...CRBE0221 12 16 17 1 2 3 5 6 7 8 9 10 13 16 14 15 4 11 PANEL FAN ASSY 250...
Page 256: ...05 0 CRBE0224 2 1 5 16 3 9 11 12 4 7 8 6 6 17 17 10 13 15 14 PANEL FAN ASSY 254...
Page 260: ...2005 ROOM AIR CONDITIONING TECHNICAL HANDBOOK...