128
-
2.1.2 SELECTION DATA
(1) Specifications
Model
SRK10CES (Indoor unit)
SRC10CES (Outdoor unit)
(2) The operation data are applied to the 220 V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is less than 10 m, add 10 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.
(4) Expressed in sound pressure level.
Notes (1) The data are measured at the following conditions.
Item
Model
SRK10CES
SRC10CES
Cooling capacity
(1)
W
2700
Power source
1 Phase, 220V, 50Hz
Cooling input
kW
0.803
Running current (Cooling)
A
4.2
Inrush current
A
18.1
COP (In cooling)
3.36
Noise level
(4)
dB
39
46
Exterior dimensions
mm
250
×
815
×
249
540
×
720
×
290
Height
×
Width
×
Depth
Color
Cool white
Stucco white
Net weight
kg
10.5
34
Refrigerant equipment
–
RMC201A002
Compressor types & Q’ty
Motor
kW
–
0.75
Starting method
–
Line starting
Heat exchanger
Louver fins & tubing
Refrigerant control
Capillary tubes
Refrigerant
(3)
kg
R22 0.75 (Pre-Charged up to the piping length of 7.5m)
Refrigerant oil
R
0.35 (ATMOS M60 or SUNISO 4GDID)
Air handling equipment
Tangential fan
×
1
Propeller fan
×
1
Fan type & Q’ty
Motor
W
14
15
Air flow (at High)
CMM
8.5
30.0
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Wireless-Remote control
–
Operation switch
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow),
–
HI POWER (Green), ECONO (Orange)
Safety equipment
Frost protection,
Compressor overheat protection
Fan motor error protection
O.D
mm (in)
Liquid line: ø6.35 (1/4") Gas line: ø9.52 (3/8")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
–
Gas line : 0.33 m
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
3 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Connection
wiring
Operation
data
(1)
Refrig
erant
piping
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27
°
C
19
°
C
35
°
C
24
°
C
ISO-T1, JIS C9612
Summary of Contents for SRK10CES
Page 2: ...TECHNICAL MANUAL...
Page 204: ...202 MEMO...
Page 213: ...211...
Page 227: ...225...
Page 233: ...231...
Page 236: ...CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY 234...
Page 244: ...CRBE0228 9 15 7 8 1 2 4 5 6 12 13 14 10 11 3 PANEL FAN ASSY 242...
Page 248: ...CRBE0227 11 15 16 1 2 3 5 6 7 8 9 12 13 14 4 10 PANEL FAN ASSY 246...
Page 252: ...CRBE0221 12 16 17 1 2 3 5 6 7 8 9 10 13 16 14 15 4 11 PANEL FAN ASSY 250...
Page 256: ...05 0 CRBE0224 2 1 5 16 3 9 11 12 4 7 8 6 6 17 17 10 13 15 14 PANEL FAN ASSY 254...
Page 260: ...2005 ROOM AIR CONDITIONING TECHNICAL HANDBOOK...