4
-
Item
Model
SRK13ZEV-S
SRC13ZEV-S
Cooling capacity
(1)
W
4000 (400~5000)
Heating capacity
(1)
W
6000 (400~9000)
Power source
1 Phase, 220V, 50Hz
Cooling input
kW
0.93 (0.105~1.5)
Running current (Cooling)
A
5.5
Heating input
kW
1.38 (0.095~2.490)
Running current (Heating)
A
6.8
Inrush current
A
6.8
COP
Cooling: 4.30 Heating: 4.35
Noise level
Cooling Sound level
46
47
Heating
Sound level
46
47
Exterior dimensions
Height
×
Width
×
Depth
mm
298
×
840
×
259
595
×
780
×
290
Color
Cool white
Stucco white
Net weight
kg
12
39
Refrigerant equipment
Compressor type & Q’ty
–
5CS102XFA (Scroll type)
×
1
Motor
kW
–
1.1
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Straight fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Refrigerant
(3)
kg
R410A 1.35 (Pre-Charged up to the piping length of 15m)
Refrigerant oil
R
0.36 (RB68A)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
33
34
(Cooling)
Air flow (at High)
(Heating)
CMM
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote control
–
Room temperature control
Microcomputer thermostat
–
Pilot light
RUN (Green), TIMER (Yellow), JET/HI POWER (Green), ION (Green)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
9.52 (3/8
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.54 m
Gas line : 0.47 m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Allergen clear filter
×
1, Natural enzyme filter
×
1)
Optional parts
–
Notes (1) The data are measured at the following conditions.
1.1.2
SELECTION DATA
(1)
Specifications
Model SRK13ZEV-S (Indoor unit)
SRC13ZEV-S (Outdoor unit)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
Heating
20ºC
–
7ºC
6ºC
ISO-T1, JIS C9612
(2) The operation data are applied to the 220V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25 m, add 20 g refrigerant per meter.
Operation data
(1)
Refrig
erant
piping
Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
The piping length is 7.5m.
(220V)
Summary of Contents for SRK10CES
Page 2: ...TECHNICAL MANUAL...
Page 204: ...202 MEMO...
Page 213: ...211...
Page 227: ...225...
Page 233: ...231...
Page 236: ...CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY 234...
Page 244: ...CRBE0228 9 15 7 8 1 2 4 5 6 12 13 14 10 11 3 PANEL FAN ASSY 242...
Page 248: ...CRBE0227 11 15 16 1 2 3 5 6 7 8 9 12 13 14 4 10 PANEL FAN ASSY 246...
Page 252: ...CRBE0221 12 16 17 1 2 3 5 6 7 8 9 10 13 16 14 15 4 11 PANEL FAN ASSY 250...
Page 256: ...05 0 CRBE0224 2 1 5 16 3 9 11 12 4 7 8 6 6 17 17 10 13 15 14 PANEL FAN ASSY 254...
Page 260: ...2005 ROOM AIR CONDITIONING TECHNICAL HANDBOOK...