11
-
(5)
Flap control
Control the flap by AIRFLOW button on the wireless remote control.
(a)
Air scroll
The flap will be automatically set to the angle of air flow best to operation.
(i)
Starting time of operation
(ii)
When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(b) Memory flap
While the flap is operating if the AIRFLOW button is pushed once, it stops swinging at an angle.
As this angle is memorized in the microcomputer, the flap will be automatically set to the angle when next operation is started.
¡
Recommendable stopping angle of the flap
(c)
Swing flap
Flap moves in upward and downward directions continuously.
s
During cooling and
t
dry operation
Thick line : Rapid movement
Thin line : Slow movement
Stops for approximately
5 seconds in the
horizontal position.
s
During heating
t
operation
Stops for approximately
5 seconds in this
position.
Thick line : Rapid movement
Thin line : Slow movement
Horizontal
blowing
COOL•DRY
Slant forward
blowing
HEAT
(4)
Custom cord switching procedure
If two wireless remote controls are installed in one room, in order to prevent wrong
operation due to mixed signals, please modify the printed circuit board in the indoor
unit’s control box and the remote control using the following procedure. Be sure to modify
both boards. If only one board is modified, receiving (and operation) cannot be done.
(a)
Modifying the indoor unit’s printed circuit board
Take out the printed circuit board from the control box and cut off jumper wire
(J2) using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other
the lead wires, etc.
(b)
Modifying the wireless remote control
i)
Remove the battery.
ii) Cut the jumper wire shown in the figure at right.
Cut
Jumper wire (J2)
Summary of Contents for SRK10CES
Page 2: ...TECHNICAL MANUAL...
Page 204: ...202 MEMO...
Page 213: ...211...
Page 227: ...225...
Page 233: ...231...
Page 236: ...CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY 234...
Page 244: ...CRBE0228 9 15 7 8 1 2 4 5 6 12 13 14 10 11 3 PANEL FAN ASSY 242...
Page 248: ...CRBE0227 11 15 16 1 2 3 5 6 7 8 9 12 13 14 4 10 PANEL FAN ASSY 246...
Page 252: ...CRBE0221 12 16 17 1 2 3 5 6 7 8 9 10 13 16 14 15 4 11 PANEL FAN ASSY 250...
Page 256: ...05 0 CRBE0224 2 1 5 16 3 9 11 12 4 7 8 6 6 17 17 10 13 15 14 PANEL FAN ASSY 254...
Page 260: ...2005 ROOM AIR CONDITIONING TECHNICAL HANDBOOK...