185
-
(d)
Explain to the customer on the correct usage of the air conditioner in simple layman’s terms.
(e)
Make sure that drain flows properly.
(f)
Standard operation data
Note (1) The data are measured at following conditions
Ambient air temperature
Indoor side: Cooling ... 27˚C DB, 19˚C WB
Outdoor side: Cooling ... 35˚C DB, 24˚C WB
(ii)
When manipulating the remote control mounted on a
wall:
Make sure that it works normally (i.e., transmission/reception
signal is audible) before mounting.
Notes (1) The remote control is correctly facing the
sensing element of the air conditioner when being
manipulated.
(2) The typical coverage is indicated (in the left
illustration). It may be more or less depending on
the installation.
(3) The coverage may be less or even nil. If the sensing
element is exposed to strong light, such as direct
sunlight, illumination, etc., or dust is deposited on
it or it is used behind a curtain, etc.
or less
5 m or less
Wireless remote
control
5 m or less
or less
(6) Precautions for wireless remote control installation and operation
(a)
Wireless remote control covers the following distances:
(i)
When operating facing the air conditioner:
or less
Model
Item
SRK19CES
SRK25CES
Low pressure (MPa)
Cooling
0.42 ~ 0.62
0.39 ~ 0.59
Temp. difference between return air and supply air (
°
C)
Cooling
11 ~ 13
12 ~ 14
Running current (A)
Cooling
8.1
10.4
If the distances exceed the area indicated above, be sure to check
the receiver status.
(5) Test run
(a)
Conduct trial run after confirming that there is no gas leaks.
(b)
When conducting trial run set the remote control thermostat to continuous operation position. However when the power source is
cut off or when the unit’s operation switch is turned off or was turned to fan operation position, the unit will not go into operation
in order to protect the compressor.
(c)
Insert in electric plug into the electric outlet and make sure that it is not loose.
(i)
When there is something wrong with the electric outlet and if the insertion of the electric plug is insufficient, there may occur
a burn out.
(ii)
It is very important to be careful of above when plugging in the unit to an already furnished electrical outlet.
(220V)
Remote control
available in this area.
Receiver
Summary of Contents for SRK10CES
Page 2: ...TECHNICAL MANUAL...
Page 204: ...202 MEMO...
Page 213: ...211...
Page 227: ...225...
Page 233: ...231...
Page 236: ...CRBE0226 1 3 4 2 5 6 7 8 9 10 11 12 13 PANEL FAN ASSY 234...
Page 244: ...CRBE0228 9 15 7 8 1 2 4 5 6 12 13 14 10 11 3 PANEL FAN ASSY 242...
Page 248: ...CRBE0227 11 15 16 1 2 3 5 6 7 8 9 12 13 14 4 10 PANEL FAN ASSY 246...
Page 252: ...CRBE0221 12 16 17 1 2 3 5 6 7 8 9 10 13 16 14 15 4 11 PANEL FAN ASSY 250...
Page 256: ...05 0 CRBE0224 2 1 5 16 3 9 11 12 4 7 8 6 6 17 17 10 13 15 14 PANEL FAN ASSY 254...
Page 260: ...2005 ROOM AIR CONDITIONING TECHNICAL HANDBOOK...