3 DESIGN
3.3 Layout Design within The Control Panel
3.3.1 Mounting environment
Mount the Motion controller system in the following environment conditions.
(1) Ambient temperature is within the range of 0 to 55[°C] (32 to 131[°F]).
(2) Ambient humidity is within the range of 5 to 95[%]RH.
(3) No condensing from sudden temperature changes
(4) No corrosive or inflammable gas
(5) There must not be a lot of conductible dust, iron filings, oil mist, or salt, organic
solvents.
(6) No direct sunlight
(7) No strong electrical or magnetic fields
(8) No direct vibrations or shocks on the Motion controller