4 - 7 4 - 7
MELSEC-Q
4 SETUP AND PROCEDURE BEFORE STARTING THE OPERATION
(2) Wiring example with a voltage output type encoder (5 V DC)
Encoder
A20(A13)
24 V
B20(B13)
12 V
A19(A12)
5 V
B19(B12)
ABCOM
Phase A
E
QD62,QD62E
A18(A11)
24 V
B18(B11)
12 V
A17(A10)
5 V
Phase B
0 V
0 V
External
power
supply
Shield
Shielded twisted pair cable
E
GND
OUT
+5 V
5 V DC
GND
OUT
Shield
Shielded twisted pair cable
The number inside the ( ) indicates the terminal number for channel 2.
(3) Wiring example with a driver (equivalent to AM26LS31) encoder
A20(A14)
A
B20(B14)
A
E
QD62D
0 V
0 V
VCC
VCC
A
A
A19(A13)
B
B19(B13)
B
E
B
B
Phase A
Phase B
External
power
supply
Shield
Shielded twisted pair cable
Shield
Shielded twisted pair cable
Encoder
The number inside the ( ) indicates the terminal number for channel 2.