APP - 37
APPENDICES
Table 1.13 Servo error (2000 to 2899) list (Continued)
Error cause
Error
code
Name Description
Error check
Error
processing
Corrective action
Initial parameter error
• The parameter setting is wrong.
• The parameter data was corrupted.
Error
code
Parameter
No.
Name
2601
PA01
For manufacturer setting
2602
PA02
Regenerative brake option
2603
PA03
Absolute position detection
system
2604
PA04
Function selection A-1
2605
PA05
For manufacturer setting
2606
PA06
For manufacturer setting
2607
PA07
For manufacturer setting
2608
PA08
Auto tuning mode
2609
PA09
Auto tuning response
2610
PA10 In-position
range
2611
PA11
For manufacturer setting
2612
PA12
For manufacturer setting
2613
PA13
For manufacturer setting
2614
PA14
Rotation direction selection
2615
PA15
Encoder output pulse
2616
PA16
For manufacturer setting
2601
2617
PA17
For manufacturer setting
to
2618
PA18
For manufacturer setting
2899
2619
PA19
Parameter write inhibit
2620
PB01
Adaptive tuning mode
2621
PB02
Vibration suppression control
filter tuning mode
2622
PB03
For manufacturer setting
2623
PB04
Feed forward gain
2624
PB05
For manufacturer setting
2625
PB06
Ratio of load inertia moment to
servo motor inertia moment
2626
PB07
Model loop gain
2627
PB08
Position loop gain
2628
PB09
Speed loop gain
2629
PB10
Speed integral compensation
2630
PB11
Speed differential
compensation
2631
PB12
For manufacturer setting
2632
PB13
Machine resonance
suppression filter 1
2633
PB14
Notch form selection 1
2634
PB15
Machine resonance
suppression filter 2
2635
PB16
Notch form selection 2
Initial
parameter
error
• Servo amplifier
power on.
• Multiple CPU
system power
on.
Immediate
stop
• After checking and
correcting of the parameter
setting, turn off to on or
reset the power of Multiple
CPU system CPU.