81
The black square (
■
) indicates a switch position.
SW2 setting
Display detail
Explanation for display
Unit
1
ON
2 3 4 5 6
LEV-A opening pulse on error
occurring
0 to 480
0 to 480
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
(Example) When 130 pulse;
0.5 s 0.5 s 2 s
30
1
Pulse
1
ON
2 3 4 5 6
Indoor room temperature (TH1) on
error occurring
46 to 102
46 to 102 [8 to 39°C]
˚F
[
:
]
1
ON
2 3 4 5 6
Indoor pipe temperature/Liquid
(TH2) on error occurring
−38 to 190
−38 to 190 [−39 to 88°C]
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 s 0.5 s 2 s
15
˚F
[
:
]
1
ON
2 3 4 5 6
Indoor pipe temperature/Cond./
Eva. (TH5) on error occurring
−38 to 190
−38 to 190 [−39 to 88°C]
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 s 0.5 s 2 s
15
˚F
[
:
]
1
ON
2 3 4 5 6
Outdoor pipe temperature/2-phase
(TH6) on error occurring
−38 to 190
−38 to 190 [−39 to 88°C]
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 s 0.5 s 2 s
15
˚F
[
:
]
1
ON
2 3 4 5 6
Outdoor outside temperature (TH7)
on error occurring
−38 to 190
−38 to 190 [−39 to 88°C]
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
(Example) When –15˚F;
0.5 s 0.5 s 2 s
15
˚F
[
:
]
1
ON
2 3 4 5 6
Outdoor heat sink temperature
(TH8) on error occurring
−40 to 327
−40 to 327 [−40 to 164°C]
(When the temperature is 0˚F or less, “–” and
temperature are displayed by turns.)
(When the temperature is 100˚F or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
˚F
[
:
]
OCH636A