82
3 SIGNALS AND WIRING
3.7 Servo motor with an electromagnetic brake
Multi-axis drive unit
*1 Do not use the 24 V DC interface power supply for the electromagnetic brake.
*2 Configure a circuit which interlocks with an emergency stop switch to shut off.
*3 This connection is for a 3-axis drive unit.
*4 Although the diagram shows the input signal and the output signal each using a separate 24 V DC power supply for illustrative purposes,
the system can be configured to use a single 24 V DC power supply.
CALM
DOCOM
MBR-A
EM2
DICOM
RA1
RA2
B
RA5
*2
B2
U
B1
EM2
RA3
RA4
MBR-B
MBR-C
B
B2
U
B1
CALM
RA1
MBR-A
RA2
MBR-B
RA3
B
B2
U
B1
MBR-C
RA4
*3
24 V DC
*4
24 V DC for
electromagnetic
brake
*1
24 V DC
*4
A-axis servo motor
B-axis servo motor
C-axis servo motor
Drive unit