![Mitsubishi Electric MR-J5D User Manual Download Page 74](http://html.mh-extra.com/html/mitsubishi-electric/mr-j5d/mr-j5d_user-manual_1811806074.webp)
72
3 SIGNALS AND WIRING
3.5 Signal (device) explanation
Power supply
Power supply explanations
■
DICOM (Digital input I/F power supply)
Input 24 V DC (24 V DC ± 10 %, 300 mA) for I/O interfaces.
For sink interfaces, connect the positive terminal of the 24 V DC external power supply.
For source interfaces, connect the negative terminal of the 24 V DC external power supply.
■
DOCOM (Digital output I/F power supply)
Input 24 V DC (24 V DC ± 10 %, 300 mA) for I/O interfaces.
For sink interfaces, connect the negative terminal of the 24 V DC external power supply.
For source interfaces, connect the positive terminal of the 24 V DC external power supply.
■
LG (Monitor common)
LG is a common terminal of MO1 and MO2.