122
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.3 Selection example of wires
Wire size selection examples
Selection examples for the 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire) are indicated below.
Refer to the following for selection examples for crossover wiring of the control circuit power supply.
Page 123 For crossover wiring of the control circuit power supply
■
400 V class
*1 The alphabetical letters in the table indicate the symbols of the selection example of crimp terminals.
Page 122 Selection example of crimp terminals
*2 For connection to the terminal block, use the screws included with the terminal block.
*3 The wires are selected based on the largest rated current among the servo motors to be combined.
*4 The minimum wire size required by the National Electrical Code is AWG 14 (2 mm
2
).
Selection example of crimp terminals
Drive unit
Wire [mm
2
]
(1) L11/L21/
U/V/W/E
MR-J5D1-100G4
1.25 to 2 (AWG 16 to 14): a
1.25 to 2 (AWG 16 to 14)
MR-J5D1-200G4
MR-J5D1-350G4
MR-J5D1-500G4
3.5 (AWG 12)
MR-J5D1-700G4
5.5 (AWG 10)
MR-J5D2-100G4
1.25 to 2 (AWG 16 to 14)
MR-J5D2-200G4
MR-J5D2-350G4
MR-J5D2-500G4
3.5 (AWG 12)
MR-J5D2-700G4
5.5 (AWG 10)
MR-J5D3-100G4
1.25 to 2 (AWG 16 to 14)
MR-J5D3-200G4
Symbol
Drive unit side crimp terminal
Manufacturer
Crimp terminal
Applicable tool
a
FVD2-4
YNT-1614
JST (J.S.T. Mfg. Co., Ltd.)