9 PDS Control Objects
9.2 [Statusword (Obj. 6041h)]
79
9
9.2
[Statusword (Obj. 6041h)]
[Statusword (Obj. 6041h: 00h)]
Description
The PDS status transition and other drive conditions are returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RO
TXMAP
0000h to FFFFh
Impossible
Bit
Symbol
Description
0
RTSO
Ready-to-switch-on
1
SO
Switch-on
2
OE
Operation-enabled
3
F
Fault
4
VE
Voltage-enabled
0: The bus voltage is lower than the specified (RA) level.
1: The bus voltage is equal to or higher than the specified level.
5
QS
Quick stop
When [Pr. PF29.1 State selection with forced stop in progress] is set to "1" (Quick stop active), the value of this
bit changes to "0" during a forced stop.
0: In a Quick stop
1: Not in a Quick stop (including in the test mode)
6
SOD
Switch on disabled
7
W
Warning
0: No warning has occurred.
1: A warning has occurred.
8
9
RM
Remote
0: Not following the Controlword
1: In operation following the Controlword
10
OMS
Differs depending on the value of [Modes of operation (Obj. 6060h)]. Refer to the following for details.
11
ILA
Internal limit active
0: The forward rotation stroke end, reverse rotation stroke end, and software position limit have not been
reached.
1: The forward rotation stroke end, reverse rotation stroke end, or software position limit has been reached.
(Enabled in the csp, csv, pp, pv, and hm mode)
12
OMS
Differs depending on the value of [Modes of operation (Obj. 6060h)]. Refer to the following for details.
13
OMS
Differs depending on the value of [Modes of operation (Obj. 6060h)]. Refer to the following for details.
14
15