8 Manufacturer Specific Control Object
8.61 [One-touch tuning mode (Obj. 2D50h)]
75
8
[Encoder ID 2 (Obj. 2D48h: 04h)]
Description
The value for manufacturer setting is returned.
8.61
[One-touch tuning mode (Obj. 2D50h)]
[One-touch tuning mode (Obj. 2D50h: 00h)]
Description
One-touch tuning command is returned and set. After one-touch tuning, the setting value automatically changes to "0".
0: One-touch tuning stop in progress
1: Basic mode
2: High mode
3: Low mode
8.62
[One-touch tuning status (Obj. 2D51h)]
[One-touch tuning status (Obj. 2D51h: 00h)]
Description
The one-touch tuning progress is returned. Regardless of whether one-touch tuning is properly completed or not, "100" is
returned at the completion.
8.63
[One-touch tuning Stop (Obj. 2D52h)]
[One-touch tuning Stop (Obj. 2D52h: 00h)]
Description
Set a one-touch tuning stop command. To check whether the setting is reflected, read [One-touch tuning mode (Obj. 2D50h)].
• 1EA5h: Stops one-touch tuning.
• Other than 1EA5h: Triggers a parameter out of range error.
When the object is read, whether one-touch tuning can be stopped is returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RO
Impossible
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RW
Impossible
00h
00h to 03h
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I8
RO
Impossible
0 to 100
%
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RW
Impossible
0000h
0000h, 1EA5h
Impossible
Bit
Description
0
0: One-touch tuning can be stopped with the command. (One-touch tuning in progress)
1: One-touch tuning cannot be stopped with the command. (One-touch tuning not in progress)
1 to 31