8 Manufacturer Specific Control Object
8.1 [Drive recorder status (Obj. 2C02h)]
51
8
8
Manufacturer Specific Control Object
8.1
[Drive recorder status (Obj. 2C02h)]
[Drive recorder status (Obj. 2C02h: 00h)]
Description
The enabled/disabled status of the drive recorder is returned.
When the drive recorder does not operate or when one-shot sampling ends in manual setting mode, this object returns "0"
(disabled status).
When the drive recorder function is operating, this object returns "1" (enabled status).
0: Disabled status
1: Enabled status
8.2
[Clear drive recorder history (Obj. 2C03h)]
[Clear drive recorder history (Obj. 2C03h: 00h)]
Description
Writing "1EA5h", cycling the power, or performing a software reset clears the data in the drive recorder history.
When the object is read, "0000h" is returned.
8.3
[Power ON cumulative time (Obj. 2C18h)]
[Power ON cumulative time (Obj. 2C18h: 00h)]
Description
Returns the cumulative energization time of the servo amplifier.
8.4
[Number of inrush relay on/off times (Obj. 2C19h)]
[Number of inrush relay on/off times (Obj. 2C19h: 00h)]
Description
The number of times that the inrush relay of the servo amplifier has been turned on/off is returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RO
Impossible
0
0 to 1
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RW
Impossible
0000h
0000h to FFFFh
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RO
Impossible
00000000h to
FFFFFFFFh
hour
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RO
Impossible
00000000h to
FFFFFFFFh
number of times
Impossible