12 Profile Torque Mode Objects
12.1 [Target torque (Obj. 6071h)]
93
12
12
Profile Torque Mode Objects
12.1
[Target torque (Obj. 6071h)]
[Target torque (Obj. 6071h: 00h)]
Description
Set the torque command used in the cyclic synchronous torque mode (cst) and the profile torque mode (tq).
12.2
[Max torque (Obj. 6072h)]
[Max torque (Obj. 6072h: 00h)]
Description
The maximum torque of the servo motor is returned.
When [Pr. PC78.1] is set to "0" (disabled), the torque limit with this object and the torque limit with the value of [Pr. PE53] will
be disabled. The values notified by this object are the maximum current and feedback values and may not match the
maximum torque described in "Rotary Servo Motor User's Manual (HK series)".
When [Pr. PC78.1] is set to "1" (enabled), the torque or thrust generated by the servo motor can be limited with the setting
value of this object.
When this object is set to "0", the torque limit is disabled.
12.3
[Torque demand value (Obj. 6074h)]
[Torque demand value (Obj. 6074h: 00h)]
Description
The torque command is returned.
12.4
[Torque actual value (Obj. 6077h)]
[Torque actual value (Obj. 6077h: 00h)]
Description
The current torque is returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RW
RXMAP
-32768 to 32767
0.1 %
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RW
TXMAP/RXMAP
0 to 10000
0.1 %
Possible
[Pr. PE53]
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
TXMAP
-32768 to 32767
0.1 %
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
TXMAP
-32768 to 32767
0.1 %
Impossible