16 Touch Probe Function Objects
16.2 [Touch probe status 2 (Obj. 2DE9h)]
16.2
[Touch probe status 2 (Obj. 2DE9h)]
[Touch probe status 2 (Obj. 2DE9h: 00h)]
Description
The status of the touch probe function is returned.
16.3
[Touch probe 3 positive edge (Obj. 2DEAh)]
[Touch probe 3 positive edge (Obj. 2DEAh: 00h)]
Description
The position latched at the rising edge of touch probe 3 is returned.
16.4
[Touch probe 3 negative edge (Obj. 2DEBh)]
[Touch probe 3 negative edge (Obj. 2DEBh: 00h)]
Description
The position latched at the falling edge of touch probe 3 is returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RO
TXMAP
0000h to 00FFh
Impossible
Bit
Description
0
0: Touch probe 3 disabled
1: Touch probe 3 enabled
1
0: The position at the rising edge of touch probe 3 has not been stored.
1: The position at the rising edge of touch probe 3 has been stored.
When the position feedback is stored in [Touch probe 3 positive edge (Obj. 2DEAh)], "1" is set.
This bit is cleared to "0" when bit 4 of [Touch probe function 2 (Obj. 2DE8h)] is set to "0".
2
0: The position at the falling edge of touch probe 3 has not been stored.
1: The position at the falling edge of touch probe 3 has been stored.
When the position feedback is stored in [Touch probe 3 negative edge (Obj. 2DEBh)], "1" is set.
This bit is cleared to "0" when bit 5 of [Touch probe function 2 (Obj. 2DE8h)] is set to "0".
3 to 5
(reserved) The value at reading is undefined.
6
Toggle status for latch completion at the rising edge of touch probe 3
0 or 1: When bit 1 of [Touch probe function 2 (Obj. 2DE8h)] is set to "1" (continuous trigger mode), the status (0 or 1) changes every time the
position feedback is stored in [Touch probe 3 positive edge (Obj. 2DEAh)].
7
Toggle status for latch completion at the falling edge of touch probe 3
0 or 1: When bit 1 of [Touch probe function 2 (Obj. 2DE8h)] is set to "1" (continuous trigger mode), the status (0 or 1) changes every time the
position feedback is stored in [Touch probe 3 negative edge (Obj. 2DEBh)].
8 to 15
(reserved) The value at reading is undefined.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RO
TXMAP
0
-2147483648 to
2147483647
pos units
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RO
TXMAP
0
-2147483648 to
2147483647
pos units
Impossible