96
13 Profile Position Mode Objects
13.1 [Target position (Obj. 607Ah)]
13
Profile Position Mode Objects
13.1
[Target position (Obj. 607Ah)]
[Target position (Obj. 607Ah: 00h)]
Description
Set the position command used in the cyclic synchronous position mode (csp) and the profile position mode (pp). Check the
setting value of [Gear ratio (Obj. 6091h)] before setting a value in this object.
13.2
[Position range limit (Obj. 607Bh)]
[Position range limit (Obj. 607Bh: 00h)]
Description
The total number of Sub Indexes (= 2) is returned.
[Min position range limit (Obj. 607Bh: 01h)]
Description
Set the range for limiting the command position.
[Position range limit (Obj. 607Bh)] cannot be written. Writing a value will result in a write error.
[Max position range limit (Obj. 607Bh: 02h)]
Description
Refer to the following object.
Page 96 [Min position range limit (Obj. 607Bh: 01h)]
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RW
RXMAP
80000000h to
7FFFFFFFh
pos units
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RO
Impossible
2
2 (fixed)
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RW
RXMAP
80000000h to
7FFFFFFFh
pos units
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RW
RXMAP
pos units
Impossible