54
8 Manufacturer Specific Control Object
8.11 [Oscillation frequency during motor stop (Obj. 2C25h)]
8.11
[Oscillation frequency during motor stop (Obj.
2C25h)]
[Oscillation frequency during motor stop (Obj. 2C25h: 00h)]
Description
The vibration frequency during stop and servo-lock is returned.
8.12
[Vibration level during motor stop (Obj. 2C26h)]
[Oscillation frequency during motor stop (Obj. 2C26h: 00h)]
Description
The vibration level during stop/servo-lock is returned.
8.13
[Oscillation frequency during motor operating
(Obj. 2C27h)]
[Oscillation frequency during motor operating (Obj. 2C27h: 00h)]
Description
The vibration frequency during operation is returned.
8.14
[Vibration level during motor operating (Obj.
2C28h)]
[Vibration level during motor operating (Obj. 2C28h: 00h)]
Description
The vibration level during operation is returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
Impossible
-32768 to 32767
Hz
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
Impossible
-32768 to 32767
0.1 %
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
Impossible
-32768 to 32767
Hz
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
Impossible
-32768 to 32767
0.1 %
Impossible