7 Monitor Objects
7.22 [Motor-side/load-side position deviation (Obj. 2B23h)]
47
7
7.22
[Motor-side/load-side position deviation (Obj.
2B23h)]
[Motor-side/load-side position deviation (Obj. 2B23h: 00h)]
Description
The motor/load-side position deviation (load-side encoder pulse unit) is returned.
7.23
[Motor-side/load-side speed deviation (Obj.
2B24h)]
[Motor-side/load-side speed deviation (Obj. 2B24h: 00h)]
Description
The motor/load-side speed deviation is returned.
7.24
[Internal temperature of encoder (Obj. 2B25h)]
[Internal temperature of encoder (Obj. 2B25h: 00h)]
Description
The internal temperature of the encoder is returned.
7.25
[Settling time (Obj. 2B26h)]
[Settling time (Obj. 2B26h: 00h)]
Description
The settling time is returned.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RO
TXMAP
80000000h to
7FFFFFFFh
pulse
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I32
RO
TXMAP
80000000h to
7FFFFFFFh
r/min
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
TXMAP
8000h to 7FFFh
°C
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
I16
RO
TXMAP
8000h to 7FFFh
ms
Impossible