10 APPLICATION OF FUNCTIONS
10.1 Compatible with MR-D30 functional safety unit
77
10
Details of MR-D30
DI_A(STOC)
DI_B(STOC)
DI_A(SLS1C)
DI_B(SLS1C)
DICOMA
DICOMA
DICOMB
DICOMB
DO24VA
DO24VB
DO_A(STOS)
DO_B(STOS)
DO_B(SLS1S)
MR-D30
Encoder master servo amplifier
STO command 1
To 0 V
To 24 V
STO command 2
SLS1 command 1
SLS1 command 2
STO output 1
STO output 2
SLS1 output
DI_A(STOC)
DI_B(STOC)
DICOMA
DICOMA
DICOMB
DICOMB
DO24VA
DO24VB
DO_A(STOS)
DO_B(STOS)
MR-D30
Encoder slave servo amplifier
STO command 1
To 0 V
To 24 V
STO command 2
STO output