![Mitsubishi Electric Melservo-J4 MR-J4-DU*B4-RJ100 Series Instruction Manual Download Page 50](http://html.mh-extra.com/html/mitsubishi-electric/melservo-j4-mr-j4-du-b4-rj100-series/melservo-j4-mr-j4-du-b4-rj100-series_instruction-manual_240840050.webp)
48
6 TROUBLESHOOTING
6.2 Troubleshooting for drive unit
46
Servo motor overheat
46.1
Abnormal temperature of servo motor 1
SD
46.2
Abnormal temperature of servo motor 2
SD
46.3
Thermistor disconnected error
SD
46.4
Thermistor circuit error
SD
46.5
Abnormal temperature of servo motor 3
DB
46.6
Abnormal temperature of servo motor 4
DB
47
Cooling fan error
47.1
Cooling fan stop error
SD
47.2
Cooling fan speed reduction error
SD
50
Overload 1
50.1
Thermal overload error 1 during
operation
SD
50.2
Thermal overload error 2 during
operation
SD
50.3
Thermal overload error 4 during
operation
SD
50.4
Thermal overload error 1 during a stop
SD
50.5
Thermal overload error 2 during a stop
SD
50.6
Thermal overload error 4 during a stop
SD
51
Overload 2
51.1
Thermal overload error 3 during
operation
DB
51.2
Thermal overload error 3 during a stop
DB
52
Error excessive
52.1
Excess droop pulse 1
SD
52.3
Excess droop pulse 2
SD
52.4
Error excessive during 0 torque limit
SD
52.5
Excess droop pulse 3
EDB
54
Oscillation detection
54.1
Oscillation detection error
EDB
56
Forced stop error
56.2
Over speed during forced stop
EDB
56.3
Estimated distance over during forced
stop
EDB
56.4
Forced stop starting error
EDB
61
Operation error
61.1
Point table setting error
DB
63
STO timing error
63.1
STO1 off
DB
63.2
STO2 off
DB
63.5
STO by functional safety unit
DB
64
Functional safety unit setting error
64.1
STO input error
DB
64.2
Compatibility mode setting error
DB
64.3
Operation mode setting error
DB
65
Functional safety unit connection
error
65.1
Functional safety unit communication
error 1
SD
65.2
Functional safety unit communication
error 2
SD
65.3
Functional safety unit communication
error 3
SD
65.4
Functional safety unit communication
error 4
SD
65.5
Functional safety unit communication
error 5
SD
65.6
Functional safety unit communication
error 6
SD
65.7
Functional safety unit communication
error 7
SD
65.8
Functional safety unit shut-off signal error
1
DB
65.9
Functional safety unit shut-off signal error
2
DB
Alarm
Details
Stop
method
*2
*3
Alarm deactivation
No.
Name
No.
Name
Alarm
reset
CPU
reset
Power
cycling
Summary of Contents for Melservo-J4 MR-J4-DU*B4-RJ100 Series
Page 2: ......
Page 75: ...9 USING STO FUNCTION 73 9 MEMO ...
Page 81: ...11 APPENDIX 11 1 Analog monitor 79 11 MEMO ...
Page 85: ......