5 MODULE DEDICATED INSTRUCTION
5.3 Serial Communication Instruction
77
5
(s2)[13]
Programmable
controller CPU
monitoring
setting
1st
* 1st block
Device code
Specify the code of the device to be monitored.
0: No device monitored
Other than 0: Device code
90H to CCH
(Device code)
User
(s2)[14]
Monitoring start device
Specify the start number of the monitoring device in
this block.
0 or more
User
(s2)[15]
(s2)[16]
Number of registered points
Specify the number of registered points (read points)
of this block.
0: No device monitored
1 or more: Number of registered points
* For a bit device, specify the number of points in
units of words.
0, 1 or more
User
(s2)[17]
Condition
agreement
transmission
Monitoring
condition
Specify the monitoring condition of this block.
0: No specification (at constant cycle transmission)
1 or more: Monitoring condition
0 to 65535
User
(s2)[18]
Monitoring
condition value
Specify the monitoring condition value for this block.
0 or more: Monitoring condition
* Specify '0' at constant cycle transmission.
0 to 000AH,
0101H to
010AH
User
(s2)[19]
User frame
output start
pointer
Specify the start pointer of the table to which the user
frame number for condition agreement transmission
for this block is set.
0: No specification (at constant cycle transmission
and notification)
1 to 100: Start pointer
0, 1 to 100
User
(s2)[20]
Number of user
frame
transmissions
Specify the number of user frame transmissions
(outputs) for condition agreement transmission for
this block.
0: No specification (at constant cycle transmission
and notification)
1 to 100: Number of transmissions
0, 1 to 100
User
(s2)[21]
Modem
connection data
No.
Specify the data number for modem function
connection when making notification in condition
agreement transmission for this block.
0: No specification (at data transmission and
constant cycle transmission)
BB8H to BD5H: Connection data number (flash
ROM)
8001H to 801FH: Connection data number (buffer
memory)
0,
BB8H to
BD5H,
8001H to
801FH
User
(s2)[22]
(s2)[102]
Programmable controller CPU monitoring setting
2nd to 10th
* 2nd to 10th block
The same item arrangement as the first
programmable controller CPU monitoring setting
item.
User
Device
Item
Setting data
Setting
range
Setting side