![Mitsubishi Electric MELSEC System Q Special Instructions Manual Download Page 95](http://html.mh-extra.com/html/mitsubishi-electric/melsec-system-q/melsec-system-q_special-instructions-manual_239154095.webp)
5 MODULE DEDICATED INSTRUCTION
5.3 Serial Communication Instruction
93
5
*1 Create a program so that the data communication process does not run while the interlock signal for communication stop is ON.
[Structured ladder/FBD]
UINI instruction command
Always sets 0
Clears control data to 0
Sets execution type
Sets CH1 transmission specification
Sets CH1 communication protocol
Sets CH2 transmission specification
Sets CH2 communication protocol
Switches mode
Sets host station number
Normal completion
Error completion
Turns interlock signal for communication stop OFF
*1
Turns interlock signal for communication stop ON
*1
Process on normal completion
Process on error completion
Data communication process