Chapter 5 Servo Drive Specifications
5–3
5-2 List of specifications
Amplifier type
MDS-B-V14L-
Capacity
class
symbol 01 03 05 10 20 35 45 70 90 110
150
Output voltage (V)
155
Continuous output
current (A)
1.4 3.0 5.0 8.8 18.2
25.0 44.0 50.0 50.0 52.0 52.0
Max. output current (A)
3.9
8.1 17.0 28.0 42.0 57.0 85.0 113 141 204 260
Control method
Sine wave PWM method
Main circuit method
Transistor, inverter (Intelligent power module using IGBT)
Braking
Dynamic brakes and deceleration to stop
Tolerable load inertia
As a guide, 2.5-times the motor inertia
Tolerable ambient
temperature
0°C to 55°C (with no freezing)
Tolerable ambient
humidity
90% (RH) or less (with no dew condensation)
Storage temperature
–15°C to 70°C (with no freezing)
Storage humidity
90% (RH) or less (with no dew condensation)
Atmosphere
Indoors (away from direct sunlight)
With no corrosive gases, combustible gases and oil mist or dust
Tolerable vibration
4.9m/s
2
Tolerable impact
Acceleration 49m/s
2
: when packaged
Max. heating amount
(W)
*26 *32 *45 *65 104 150 208 318 370 400 550
Weight
(kg)
3.5 3.5 3.5 4.5 4.5 4.5 6.0 7.0 7.0 10.0
10.0
Capacity
(kW)
0.1 0.3 0.5 1.0 2.0 3.5 4.5 7.0 9.0 11.0
15.0
Torque limit range
0 to 100%
Noise dB (A)
Within 55dB
(Note 1)
The heating amount is the value for the rated output.
(Note 2)
When installed in a sealed state, the guide for the heating amount outside the panel must
be calculated with the following expression.
Heating amount outside panel =
(Max. heating amount described in specifications above – 15) × 0.85
Note that the units marked with a * in the above specifications do not have a fin, so the
heating amount is only for inside the panel.
(Note 3)
Due to the structure, heat will easily accumulate in each unit. Thus, install a fan in the power
distribution panel to agitate the heat at the top of the unit. (Velocity 2m/s or more)
CAUTION
The MDS-B-V14L-110 and MDS-B-V14L-150 do not have built-in dynamic
brakes. An external dynamic brake unit must be provided.
Refer to the section 5-6 Dynamic brake unit.