Chapter 8 Drive Section Connector and Cable Specifications
8–10
8-2-6 Flexible conduits
Basically, splash proofing can be ensured if cab-tire cable and connectors with IP65 or higher
specifications are used. However, to further improve the oil resistance (chemical resistance to oil),
weather resistance (resistance to the environment when used outdoors, etc.), durability, tensile
strength, flattening strength, etc., run the cable through a flexible conduit when wiring.
The following shows an example of a flexible conduit. Contact the connector maker for more
information.
(1) Method for connecting to a connector with back shell
Cable
Connector with
back shell
Flexible conduit
Connector
for conduit
Type
DDK Japan
Flex
Application Applicable
motors
Connector
(straight)
Connector
(angle)
Connector for
conduit
Flexible conduit
RCC-104CA2022
VF-04 (Min. inside dia.: 14)
For
LM-NP2S
LM-NP2M
LM-NP2L
CE05-6A22-23S
D-B-BSS
CE05-8A22-23S
D-B-BAS
RCC-106CA2022
VF-06 (Min. inside dia.: 19)
RCC-106CA2428
VF-06 (Min. inside dia.: 19)
For power
supply
For
LM-NP4S
LM-NP4M
LM-NP4L
CE05-6A24-10S
D-B-BSS
CE05-8A24-10S
D-B-BAS
RCC-108CA2428
VF-08 (Min. inside dia.:
24.4)
(Note)
None of the parts in this table can be ordered from Mitsubishi Electric Corp.
(2) Method for connecting to the connector main body
Cable
Flexible conduit
Connector
for conduit
Connector
Type
DDK
DAIWA DENGYO Co., Ltd.
Application Applicable
motors
Connector (straight)
Connector for conduit
Flexible conduit
BOS-22-15
(Straight)
BOL-22-15 (Angle)
MPF15 (Min. inside dia.: 14.2)
For
LM-NP2S
LM-NP2M
LM-NP2L
CE05-6A22-23SD-B
BOS-22-19
(Straight)
BOS-22-19 (Angle)
MPF19 (Min. inside dia.: 17.2)
BOS-24-19
(Straight)
BOL-24-19 (Angle)
MPF19 (Min. inside dia.: 17.2)
For power
supply
For
LM-NP4S
LM-NP4M
LM-NP4L
CE05-6A24-10SD-B
BOS-24-25
(Straight)
BOL-24-25 (Angle)
MPF25 (Min. inside dia.: 23.5)
(Note)
None of the parts in this table can be ordered from Mitsubishi Electric Corp.