61
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
ENGLISH
■
Operation example 2
Setting the holiday.
< Operation >
• REC MODE A (normal recording with all the cameras) is
set to Monday to Friday from 08:00 to 15:00, and REC
MODE B (normal recording with camera numbers “
1
” and
“
3
”) is set from 15:00 to 20:00.
• On weekends, REC MODE B (normal recording with cam-
era numbers “
1
” and “
3
”) is set from 08:00 to 17:00.
• 31/12, 1/1, 2/1 and 3/1 are set as holidays and REC MODE
B is set from 08:00 to 17:00.
From Monday
to Friday
Saturday and
Sunday
08:00
17:00
08:00
15:00
20:00
REC MODE A
REC MODE B
08:00
17:00
REC MODE B
REC MODE B
Holiday
(31/12, 1/1,
2/1, 3/1)
< Setting >
1) Set 1) to 3) of “Operation example 1” on the previous
page.
2) <TIMER PROGRAM SETTINGS> screen setting (
see pages 44 to 46)
• SELECTED PATTERN: “P2”
• HOLIDAY SETTING: 31/12, 01/01, 02/01, 03/01
<TIMER PROGRAM SETTINGS>
>>SELECTED PATTERN P2-SET
HOLIDAY SETTING
REC MODE A
REC MODE B
REC MODE C
REC MODE D
ALARM REC DURATION 5S
<HOLIDAY SETTING>
31/12 01/01 02/01 03/01
--/-- --/-- --/-- --/--
--/-- --/-- --/-- --/--
--/-- --/-- --/-- --/--
--/-- --/-- --/-- --/--
DAY/MONTH
3) Set 5) and 6) of “Operation example 1.”
4) <TIMER PROGRAM> screen setting (
see page 44)
• PROGRAM NO.1 : “SPL,” “08:00,” “15:00,” “A,” “OFF.”
• PROGRAM NO.2 : “SPL,” “15:00,” “20:00,” “B,” “OFF.”
• PROGRAM NO.3 : “SAT,” “08:00,” “17:00,” “B,” “OFF.”
• PROGRAM NO.4 : “SUN,” “08:00,” “17:00,” “B,” “OFF.”
• PROGRAM NO.5 : “HOL,” “08:00,” “17:00,” “B,” “OFF.”
• SPL: “MON - FRI”
<TIMER PROGRAM> P2
DW START END MODE MD
>>1 SPL 08:00 15:00 A OFF
2 SPL 15:00 20:00 B OFF
3 SAT 08:00 17:00 B OFF
4 SUN 08:00 17:00 B OFF
5 HOL 08:00 17:00 B OFF
6 --- --:-- --:-- ---- ---
7 --- --:-- --:-- ---- ---
8 --- --:-- --:-- ---- ---
SPL MON-FRI
When completed with all the settings above and after
clearing the menu screen, press both the TIMER ON/
OFF buttons. The unit switches to the timer
programming mode.
■
Operation example 3
Setting a combination of normal recording, pre-alarm
recording, alarm recording and emergency recording.
< Operation >
• REC MODE C (pre-alarm recording, alarm recording and
emergency recording, with all the cameras) is set from
Monday to Friday from 08:00 to 15:00 and REC MODE D
(pre-alarm recording, alarm recording, and emergency
recording with camera numbers “
1
” and “
3
”) is set from
15:00 to 08:00 on the next day.
• On weekends, REC MODE D (pre-alarm recording, alarm
recording, and emergency recording with camera numbers
“
1
” and “
3
”) is set from 08:00 to 08:00 on the next day.
Next day
08:00
Next day
08:00
REC MODE C
REC MODE D
REC MODE D
From Monday
to Friday
Saturday and
Sunday
08:00
08:00
15:00
< Setting >
1) Set 1) to 3) of “Operation example 1.”
2) <REAR TERMINAL SETTINGS> screen setting (
see
page 51)
• EMERGENCY REC DURATION: “20M”
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
MODE OUT 5 OFF
KEY SOUND ON
BUZZER OFF
REMAIN HDD MAIN-10
%
CALL OUT SETTINGS
>>EMERGENCY REC DURATION 20M
3) Set each item in the <MOTION DETECTION SET-
TINGS> screen for all the cameras (
see pages 38 to
40).