![Mitel SmarT-1 50000241 Installation And Programming Manual Download Page 52](http://html.mh-extra.com/html/mitel/smart-1-50000241/smart-1-50000241_installation-and-programming-manual_1807035052.webp)
Access Control Sequences
8380-383-115-BA
51
Issue 1, February 1999
9. 3. Access Control Sequences (6R5)
Access Control Sequences (ACS) instruct the Dialer on how to access a particular carrier-
telephone network. Calls are routed in the ACS after a match in the Search Tables is detected.
Each entry (6R5) can be any sequence of commands taken from the following tables, with a
maximum of 80 characters per entry.
Register
Token
Description
6R5
Where R
Equals
1 - 8 for
Routes
1 - 8
See
Section
9.2.
0
1
2
3
4
5
7
8
9
D
✳
06N
✳
07N
✳
08
✳
09
✳
1
✳
2
✳
3
✳
4XY
✳
5XNN
✳
7
✳
8
✳
9
#0
✳
#00
#01
#02
#03
#06
#07
#08
#1CD
#25B
#3AB
#4AB
#5AB
#6AB
#7AB
#8AB
#CAB
#
✳
AB
Dial the digit 0
Dial the digit 1
Dial the destination number (up to 106 digits)
Dial the route access code (Register 6R1)
Dial the authorisation number (Register 6R2)
Dial the cost centre code (up to 22 digits)
Through connect (finished dialling)
Change to MF4 dialling
Dial the contents of Register 6R4)
Character string (refer to page
Wait the value of “N” x 100 ms (refer to page 52)
Wait the value of “N” x 1 second (refer to page 52)
Drop and reseize Exchange Line
Hook flash to PABX/Centrex (refer to page 41)
Set MF4 dialling rate #1 via Register 102
Set MF4 dialling rate #2 via Register R60/R80
Set MF4 dialling rate #2 via Register R61/R81
Set tone for programmed tone detector ††
Set Callback (refer to page
Dial the contents of Register 6R7 (refer to pag e56)
Dial the contents of Register 6R8 (refer to pag e56)
Dial the contents of Register 6R9 (refer to pag e56)
Dial a
✳
(MF4)
Dial # (MF4)
Dial a # if the last digit dialled out was not a #
Wait for cost centre code (does not dial the code)
Wait for end of destination digits
Dial the PABX/Centrex select digits buffer
Dial the Primary select digits buffer
Dial teh Alternate select digits buffer
MF4 digit detector †††
Pause for the “B” time and then continue †
570 - 680 Hz tone detector †
440 Hz tone detector †
425 Hz local tone detector †
400 Hz tone detector †
350 - 620 Hz tone detector †
330 + 440 Hz special/second dial tone detector †
2100 Hz broad band tone detector †
Programmable tone detector ††
† Refer to the table on page 52 for dial tone timer parameters.
†† The *4XY and the #*AB tokens must be used together. Refer to page 54 for an example.
††† Refer to page 53 for the description of the MF4 tone detector.
Summary of Contents for SmarT-1 50000241
Page 8: ...Table of Contents 8380 383 115 BA 7 Issue 1 February 1999 ...
Page 12: ...Safety Information 8380 383 115 BA 11 Issue 1 February 1999 ...
Page 18: ...SMarT 1 EuroRoute One line Dialer Installation 8380 383 115 BA 17 Issue 1 February 1999 ...
Page 20: ...System Requirements 8380 383 115 BA 19 Issue 1 February 1999 ...
Page 24: ...Initialisation 8380 383 115 BA 23 Issue 1 February 1999 ...
Page 28: ...Security Access Registers 8380 383 115 BA 27 Issue 1 February 1999 ...
Page 50: ...Line and Trunk Options 8380 383 115 BA 49 Issue 1 February 1999 ...
Page 58: ...Access Control Sequences 8380 383 115 BA 57 Issue 1 February 1999 ...
Page 68: ...Search Tables 8380 383 115 BA 67 Issue 1 February 1999 ...
Page 72: ...Common Option Data 8380 383 115 BA 71 Issue 1 February 1999 ...
Page 78: ...Cost Centre Code Options 8380 383 115 BA 77 Issue 1 February 1999 ...
Page 86: ...Appendix 2 Default Data 8380 383 115 BA 85 Issue 1 February 1999 ...
Page 90: ...Appendix 4 Hardware Specifications 8380 383 115 BA 89 Issue 1 February 1999 ...