![Mitel SmarT-1 50000241 Installation And Programming Manual Download Page 53](http://html.mh-extra.com/html/mitel/smart-1-50000241/smart-1-50000241_installation-and-programming-manual_1807035053.webp)
Access Control Sequences
8380-383-115-BA
Issue 1, February 1999
52
9. 4. A and B Dial Tone Detection Parameters
9. 4. 1. A and B Dial Tone Detection Parameters
The Dialer expects a certain minimum duration of dial tone to occur within a specified time
before attempting to dial. They are specified by the A and B timers in the first set of tables
below.
9. 4. 2. Example
Route 0 (615) is programmed with #56227. The ACS string is made up of :
•
#562
Wait for 200 ms of 425 Hz dial tone, for up to four seconds
•
2
Dial destination number
•
7
Through connect
9. 5. Character String
The Dialer has an Access Control Sequence (ACS) Token that allows character strings to be
contained in the ACS. This token may be used in the 6r5 ACS string.
9. 5. 1. Example
In the string D1234D:
•
D
is the ACS Token (it must appear before and after the string)
•
1234
are the digits that are dialled.
9. 6. Programmable 100 ms Wait Timer
The
✳
06N tells the Dialer to wait for “n” times 100 milliseconds.
9. 7. Programmable 1 Second Wait Timer
The
✳
07N tells the Dialer to wait for “n” times 1 second.
A
Minimum Tone Duration
B
Time Dial Tone must be Detected In
0 = minimum; redial per R58/R78 †
1 = 200 ms; redial per R58/R78 †
2 = 400 ms; redial per R58/R78 †
3 = 1.0 sec; redial per R58/R78 †
4 = 2.55 sec; redial per R58/R78 †
2 for 4 sec 9 for 18 sec
3 for 6 sec
✳
for 20 sec
4 for 8 sec # for 20 sec
5 for 10 sec C for 24 sec
6 for 12 sec D for 26 sec
7 for 14 sec E for 28 sec
8 for 16 sec F for 30 sec
5 = minimum; then continue dial out
6 = 200 ms; then continue dial out
7 = 400 ms; then continue dial out
8 = 1.0 sec; then continue dial out
9 = 2.55 sec; then continue dial out
† Refer to page 68 for more information on R58/R78.
Summary of Contents for SmarT-1 50000241
Page 8: ...Table of Contents 8380 383 115 BA 7 Issue 1 February 1999 ...
Page 12: ...Safety Information 8380 383 115 BA 11 Issue 1 February 1999 ...
Page 18: ...SMarT 1 EuroRoute One line Dialer Installation 8380 383 115 BA 17 Issue 1 February 1999 ...
Page 20: ...System Requirements 8380 383 115 BA 19 Issue 1 February 1999 ...
Page 24: ...Initialisation 8380 383 115 BA 23 Issue 1 February 1999 ...
Page 28: ...Security Access Registers 8380 383 115 BA 27 Issue 1 February 1999 ...
Page 50: ...Line and Trunk Options 8380 383 115 BA 49 Issue 1 February 1999 ...
Page 58: ...Access Control Sequences 8380 383 115 BA 57 Issue 1 February 1999 ...
Page 68: ...Search Tables 8380 383 115 BA 67 Issue 1 February 1999 ...
Page 72: ...Common Option Data 8380 383 115 BA 71 Issue 1 February 1999 ...
Page 78: ...Cost Centre Code Options 8380 383 115 BA 77 Issue 1 February 1999 ...
Page 86: ...Appendix 2 Default Data 8380 383 115 BA 85 Issue 1 February 1999 ...
Page 90: ...Appendix 4 Hardware Specifications 8380 383 115 BA 89 Issue 1 February 1999 ...