13. 8. Call Home Examples
13. 8. 1. Example One
This example sets a Dialer to Call Home every day at 2300 hours. The Dialer will send modem
tone immediately, so that as soon as the remote end answers it can be connected to a modem.
When the CONNECT message is displayed, a valid terminal password can be entered, in order
to start the programming session.
The Dialer will auto-answer after the time defined in the 127 Register is expired, and it will
immediately put out modem tone for the time defined in the 005 Register. After the Dialer
connects, it will wait for the time defined by the 128 Register, and if the Dialer connects wait
for the Terminal Security Code (Register 604). If the time defined by the 128 Register has
expired, you will be unable to enter a password.
•
003 0
Direct dial the contents of Register 600
•
004 9
Send modem originate tone immediately
•
005 3
Thirty seconds of modem tone
•
014 1
Call Home enabled
•
980 MMDDHHMM
System Clock
•
600 08001234567 ##
Call Home Number
•
608 002300 ##
Call Home daily at 2300 hours
•
128 6
Dialer will wait 60 seconds for the Terminal
Security Code
•
129 0
Lockout is disabled after failure.
13. 8. 2. Example Two
This example sets a Dialer to Call Home on the first day of each month at 2215 hours, using
Route 7. In order to start the modem, the Remote Access Code (Register 606) will have to be
entered (it will act as an MF4 modem wake-up code). When the CONNECT message is
displayed, a valid terminal password can be entered, in order to start the programming session.
The Dialer will auto-answer after the time defined by the 127 Register is expired, after which
time it will expect the Remote Access Code before the time defined by the 128 Register
expires. If the time defined by the 128 Register expires, you will be unable to enter the Access
Code. If the Access Code is entered, the Dialer will put out modem tone for the time defined
by the 128 Register, and if the Dialer connects then it will wait for the Terminal Security Code
(Register 604). If the time defined by the 128 Register expires, you will be unable to enter the
Terminal Security Code.
•
003 8
Call Home using Route 7 (ACS 685)
•
004 0
No delay before Remote Access Code expected
•
005 3
Thirty seconds of modem tone
•
014 1
Call Home enabled
•
980 MMDDHHMM
System Clock
•
681 08001234567 ##
Call Home Number
•
685 #80237##
Route 7 dialing rule
•
608 012215##
Date and time to Call Home
•
128 3
Dialer will ring for 60 seconds
•
129 0
Lockout is disabled after failure.
Summary of Contents for SmarT-1 50000241
Page 8: ...Table of Contents 8380 383 115 BA 7 Issue 1 February 1999 ...
Page 12: ...Safety Information 8380 383 115 BA 11 Issue 1 February 1999 ...
Page 18: ...SMarT 1 EuroRoute One line Dialer Installation 8380 383 115 BA 17 Issue 1 February 1999 ...
Page 20: ...System Requirements 8380 383 115 BA 19 Issue 1 February 1999 ...
Page 24: ...Initialisation 8380 383 115 BA 23 Issue 1 February 1999 ...
Page 28: ...Security Access Registers 8380 383 115 BA 27 Issue 1 February 1999 ...
Page 50: ...Line and Trunk Options 8380 383 115 BA 49 Issue 1 February 1999 ...
Page 58: ...Access Control Sequences 8380 383 115 BA 57 Issue 1 February 1999 ...
Page 68: ...Search Tables 8380 383 115 BA 67 Issue 1 February 1999 ...
Page 72: ...Common Option Data 8380 383 115 BA 71 Issue 1 February 1999 ...
Page 78: ...Cost Centre Code Options 8380 383 115 BA 77 Issue 1 February 1999 ...
Page 86: ...Appendix 2 Default Data 8380 383 115 BA 85 Issue 1 February 1999 ...
Page 90: ...Appendix 4 Hardware Specifications 8380 383 115 BA 89 Issue 1 February 1999 ...