9.3 Drive Control Unit
ATECH / ZAPI
•15) DRIVER 1 KO
15) DRIVER 1 KO
•If voltage at connection NT1 (A11) does not correspond to determined value, an alarm
is output and the system switches off.
•Possible causes:
•
a) Wire broken at connection NT1 (A11) or coil of reverse direction contactor
is defective.
b) The internal MOSFET driver is short-circuited (replace controller!)
•16) DRIVER 1 SIC KO
•If current load at contactor driver controlling the output NT1 (A11) is excessive, an
alarm is output and the system switches off.
•Possible causes:
•Possible causes:
a) Short-circuit of the wire at connection NT1 (A11) to +Batt
•
b) Coil of connected contactor short-circuited or current consumption > 5A
63
Summary of Contents for ERIDE 30
Page 19: ...3 Technical Data 19 ...
Page 38: ...7 Mechanical Components 7 1 Squeegee Fig 7 1 38 ...
Page 40: ...7 1 Mechanical Components 7 1 Squeegee Abb 30 Fi 7 3 Abb 30 Fig 7 2 Fig 7 3 Fig 7 2 40 ...
Page 44: ...7 2 Forward and Reverse Switch The pictures below show the wiring of the switch 44 ...
Page 45: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 45 ...
Page 46: ...7 3 Mechanical Components 7 3 Brush Head Lifting Unit 46 ...
Page 76: ...11 Adjustment of Disk Brake 76 ...
Page 80: ...12 2 Notes 80 ...