5.
Cleaning Programs (FPV)
The cleaning programs define the behavior of the water supply to the brushes, the
brush motors in respect of the position of the drive direction switch, the drive
potentiometer (forwards, neutral, reverse) and the squeegee.
The drive direction switch S07 and drive potentiometer switch S08 provide a 24 V
signal for forward drive at input A01.X10:4 and for reversing at input A01.X10:5.
If no voltage signal is applied, the cleaning units are not activated.
The reaction of the cleaning functions is described in Table 5.1.
To select a cleaning program, access the programming level as described in Chapter
2.2.4. The cleaning programs available are listed in Table 5.2.
T
h
B tt
3 f
i
3
d
Th
di
t
To save any program changes, press Button 3 for min. 3 seconds. Then disconnect
the diagnostics connector from A1.
25