9.3 Drive Control Unit
ATECH / ZAPI
•11) HIGH CURRENT
11) HIGH CURRENT
•Test in rest state – contactor open;
•If measured current is >50A, alarm is output and the system switches off. The current
sensor is defective (replace controller!)
•12) PEDAL WIRE KO
•If no voltage is measured at pin NPOT (A12), to which the negative wire of the
potentiometers is connected, an alarm is output.
p
p
•Possible causes:
•
a) Wire rupture at pin PPOT (A14)
•
b) Wire rupture at pin NPOT (A12)
) P t
ti
t
i d f
ti
(i fi it
i t
)
•
c) Potentiometer is defective (infinite resistance)
•
d) Potentiometer resistance >47 kOhm