8. Water Pump
•To control the function of the water pump, the voltage for the individual levels can be
To control the function of the water pump, the voltage for the individual levels can be
disconnected at the central electronics unit (A1.X11:4+11). The following results are
achieved when measuring with a True RMS measuring instrument and water in the tank
but with the suction turbines switched off:
•
Disk brush
•
Level 1:
Approx. 3.5 V
•
Level 2:
Approx. 4.2 V
•
Level 3:
Approx. 5.1 V
Level 3:
Approx. 5.1 V
•
Level 4:
Approx. 7.6 V
•
Level 5:
Approx. 9.8 V
•
Level 6:
Approx. 15.2 V
•
•However, the measured values determined in the machines could deviate from the
values achieved in practice. A more reliable method for controlling the water pump is to
measure the water quantities actually fed.