34
Chapter 6. Machine adjustment and setting up
GB
DIAGNOSTIC MENU
-> UTILITY
->
STATUS
->
ALARMS
-> OUTPUTS
-> INPUTS
UTILITY
Config. Lock: NO
-> RESET TO DEFAULT
NO: the configuration is not blocked. All set
parameters can be changed.
YES: the configuration is blocked. None of the
parameters can be changed.
Allows restoring default values
Press the button (S).
Once the parameters have been changed press the stop button
(5) to return to the DIAGNOSTIC MENU.
DIAGNOSTIC MENU
->
UTILITY
-> STATUS
->
ALARMS
-> OUTPUTS
-> INPUTS
STATUS
Cycles:
000000
Oil: 12000
Stop:
000000
On time: 000000
Cycle time: 000000
Warranty: 01/01/11
The following are displayed:
Total number of cycles performed by machine.
Number of cycles after which the OIL alarm trips.
Number
of cycles after which the machine can be blocked.
Total number of hours of activity of machine.
Total number of machine cycle hours.
End of machine warranty.
Press the button
(
▼
)
to
switch to
STATUS function.
Now press the button (S).
Press the stop button (5) to return to the
DIAGNOSTIC MENU.
DIAGNOSTIC MENU
->
UTILITY
->
STATUS
-> ALARMS
-> OUTPUTS
-> INPUTS
ALARM
Gas pressure:
OK
Vacuum time:
OK
Soldering time:
OK
Pump time:
OK
The state of the alarms is displayed:
OK: Correct operation
AL: Alarm tripped due to fault.
Press the button
(
▼
)
to switch to
ALARMS function.
Now press the button (S).
Press the stop button (5) to return to
the DIAGNOSTIC MENU.
DIAGNOSTIC MENU
->
UTILITY
->
STATUS
->
ALARMS
-> OUTPUTS
-> INPUTS
OUTPUT
Vacuum valve:
[
]
Air valve:
[ ]
Gas valve:
[ ]
Soldering valve:
[ ]
Soft-air valve:
[ ]
Vacuum pump:
[ ]
The correct operation of the outputs can be checked
as follows:
Using the buttons (
▼
) and (
▲
) position the cursor
on each output and press the button (
►
).
[
X
] appears and, if correctly operating, you will
hear the contact of the diagnosed output open.
Press the button (
◄
) to close the contact.
Press the button
(
▼
)
to switch to
OUTPUT function.
Now press the button (S).
Press the stop button (5) to return to the
DIAGNOSTIC MENU.
DIAGNOSTIC MENU
->
UTILITY
->
STATUS
->
ALARMS
->
OUTPUTS
-> INPUTS
INPUT
Microswitch: OFF
Pressure switch: OFF
The correct operation of the inputs can be checked
as follows:
Press the lid micro contact and/or disconnect the
pressure switch.
Press the button
(
▼
)
to switch to
INPUTS function.
Now press the button (S).