Chapter 6. Machine adjustment and setting up
GB
6.1.3. Program selection and variable setting
6.1.3.1. Main display page (page one)
PROGRAM:
P02
Time:
Vacuum limit:
Vacuum:
Residual:
Extra-vacuum:
Gas ratio:
Press the buttons
(
►
)
and
(
◄
)
to select the
“Program”
(e.g. P02).
PROGRAM:
P02
Time:
0.2
sec
Vacuum limit:
Vacuum:
Residual:
Extra-vacuum:
Gas ratio:
Press the button (
▼
) to switch to the
“Time”
sealing function.
Press the buttons (
►
) and (
◄
) to set the “Sealing time” (0.0 ÷ 4).
For the first work cycles, it is best to set a sealing time of about 2.2 seconds, and then
lower it, so as to prevent burning the Teflon tape.
PROGRAM:
P02
Time:
0.2 sec
Vacuum limit:
100.0
%
Vacuum:
Residual:
Extra-vacuum:
Gas ratio:
Press the button (
▼
) to switch to
“Vacuum limit”
function.
Press the buttons (
►
) and (
◄
) to set the required vacuum limit (000.0 ÷ 100.0).
The recommended vacuum value is 100.0.
PROGRAM:
P02
Time:
0.2 sec
Vacuum limit:
100.0%
Vacuum:
000.0
%
Residual:
Extra-vacuum:
Gas ratio:
Press the button
(
▼
)
to switch to the “
Vacuum
” function.
By pressing the buttons
(
►
)
and
(
◄
)
the vacuum setting can be displayed. This is
achieved in 2 ways:
000.0%: displays the percentage of vacuum achieved inside the tank (100%
corresponds to max vacuum achieved).
1000mbar: displays the pressure inside the tank (0mbar corresponds to the max
vacuum achieved).
PROGRAM:
P02
Time:
0.2 sec
Vacuum limit:
100.0%
Vacuum: 000.0%
Residual:
100.0
%
Extra-vacuum:
Gas ratio:
The value of the
“Residual”
function cannot be modified.
Displays the difference between set vacuum limit and the current limit during the
packaging phase.
PROGRAM:
P02
Time:
0.2 sec
Vacuum limit:
100.0%
Vacuum:
X=45
000.0%
Residual:
100.0%
Extra-vacuum:
45
sec
Gas ratio:
Press the button
(
▼
)
to switch to the “
Extra-vacuum
” function.
Press the buttons
(
►
)
and
(
◄
)
to set the “
Extra-vacuum
” time (0 ÷ 45 seconds)
only with “Vacuum limit” of 100.0.
This is the time the pump continues to extract air from inside the bell after the machine
has achieved the set vacuum level.
The letter X followed by the extravacuum time in seconds is displayed next to
“Vacuum”.
This function is useful for porous products in which air extraction is particularly difficult
(e.g.,: meat).
PROGRAM:
P02
Time:
0.2 sec
Vacuum limit:
100.0%
Vacuum: 000.0%
Residual:
100.0%
Extra-vacuum: 00 sec
Gas ratio:
000.0
%
Press the button (
▼
) to switch to “
Gas rate
” function.
A value can be set from 0 to 40%.
This value represents the percentage of gas inside the pack.
After the gas introduction phase, a residual vacuum can remain of min 60%.
Note: the gas value can be increased by means of a password (contact the supplier).
This change is only possible by applying an external compressor.
If the gas LED (2) flashes this means the gas tank is not correctly connected or the
pressure is too low and the machine fails to start. Restore the correct connection.
Now press the (
▼
) to access the next page.