Image shows an example of the control unit crawler pressure gauge:
Pressurising CAM026
1
Connect the Proteus
™
Lite inspection system and apply power.
2 Unscrew the pressure valve protection cap (
B
) and screw on the pressure valve
connection adaptor (
A)
.
3
Set the pressure regulator for the CO
2
or Nitrogen to 5 PSI.
4
Ensure the crawler pressure is within the acceptable range by checking the
pressure gauge on the control unit. An example is shown below. Refer to the
CCU section of this manual on specific instructions on how to access the
pressure gauges.
5
Remove the pressure valve connection adaptor (
A)
.
6
Refit the pressure valve protection cap (
B
).
A
B