V
2. Power supply
WARNING
Turn off power before connecting or disconnecting cables.
Leaving power on may result in electric shock or equipment damage.
WARNING
Before turning on power, confirm that the power supply specifications match the power supply
specifications for the equipment.
Contact with us if the specifications do not match. Using an unconfirmed power supply may result in
electric shock or equipment damage.
CAUTION
Always ground the equipment.
Failure to ground the equipment may result in electric shock or malfunctions.
3. Precautions
CAUTION
Always set the sensor or pressure transmitting pin using the software before first use or after
replacing them. Failure to set the equipment may result in incorrect measurements, equipment
malfunctions, and damage to peripheral equipment. Likewise, reset the equipment if it has been set
once but gives incorrect results.
CAUTION
Confirm that the wiring is correctly connected before attempting to use the equipment. Incorrect
wiring of the equipment may lead to incorrect measurements, equipment malfunctions, damage to
peripheral equipment, and serious accidents.
CAUTION
Altering the settings while carrying out measurements using the equipment will result in incorrect
measurements, equipment malfunctions, and damage to peripheral equipment.
CAUTION
Protect the equipment from impact or shock—for example, impact or shock caused by striking against
other objects.
Impact or shock may damage the equipment and lead to failures in the electrical circuits.
CAUTION
Do not remove the equipment case cover or attempt to disassemble the equipment.
Doing so may damage the case and affect durability and operations.
This system saves measurement data to a PC memory storage device (e.g., hard disk drive).
Periodically sort out stored data to prevent freezing or degradation of PC performance.
To prevent communication errors, always shut down the measurement software before turning off the
equipment power or disconnecting the USB cable connecting the equipment and PC.
Summary of Contents for MPC-201-25
Page 1: ...Molding Pressure Conversion Module MPC 201 25 Instruction Manual EN294 1697G ...
Page 2: ......
Page 14: ...XII ...
Page 18: ...XVI 24 4 Vertically positioning the ejector plate 102 24 5 Removing a sensor 103 ...
Page 33: ...15 3 Right click to display the context menu and select Properties ...
Page 34: ...16 4 Click on Update Driver in the Driver tab 5 Select Browse my computer for driver software ...
Page 43: ...25 5 Overlay screen 6 Trend Peak Pressure screen 7 Trend Integral screen ...
Page 122: ......
Page 123: ......