8
5-2-2.
External Control Input/Output Connection
Check that the power has not been turned on, and connect the external control input/output.
* Compatible plug provided: XW4B-09C1-H1 (Omron)
* COM1 and COM2 are interconnected internally, and are separate from COM3.
(1) Input connection
* Insulated by photocoupler from internal circuit.
(2) Output connection
* Open collector rating V
CE
= 35 V DC max, I
C
= 100 mA DC max
* Insulated by photocoupler from internal circuit.
Use shield cable for the I/O cable, and connect the shield wire to the protective ground terminal.
Marking on casing
Description
F.G.
Frame ground
(Case protective ground
terminal and
F.G. terminal are linked.)
DC24 V
24 V DC power supply
(20.4 V
~
27.6 V DC)
DC0 V
0 V power supply
IN1
Start trigger signal input
COM1
Signal ground (for IN1)
IN2
Alarm cancel signal input
COM2
Signal ground (for IN2)
OUT Alarm
signal
output
COM3
Signal ground (for OUT)
COM 3
OUT
Surge protector
Load
V
CE
or
1 k
Ω
0.047 uF
10 k
Ω
+24 V
COM 1
~
2
IN 1
~
2
Summary of Contents for MPC-201-25
Page 1: ...Molding Pressure Conversion Module MPC 201 25 Instruction Manual EN294 1697G ...
Page 2: ......
Page 14: ...XII ...
Page 18: ...XVI 24 4 Vertically positioning the ejector plate 102 24 5 Removing a sensor 103 ...
Page 33: ...15 3 Right click to display the context menu and select Properties ...
Page 34: ...16 4 Click on Update Driver in the Driver tab 5 Select Browse my computer for driver software ...
Page 43: ...25 5 Overlay screen 6 Trend Peak Pressure screen 7 Trend Integral screen ...
Page 122: ......
Page 123: ......