50
9-2-4.
Alarm Output Condition Settings
Use either monitoring zone or integral pressure to perform alarm monitoring.
If the monitoring conditions are met, an alarm signal is output.
(1) Alarm monitoring using zone
Setting Description
Monitoring
zone
Monitoring 1
Monitoring 2
Monitoring 3
Type
Area
*1
Outputs an alarm if the pressure falls
outside the upper or lower limits set
within the monitoring period.
Peak
Outputs an alarm if the waveform data
peak falls outside the upper or lower
limits set within the monitoring period.
Point
*2
Outputs an alarm if the pressure falls
outside the upper or lower limits after
the monitoring period.
Time to
peak
*3
Outputs an alarm if the time taken to
reach the peak within the measuring
period is outside the preset time.
Pressure
Sets upper and lower values.
Time
Sets monitoring start and finish times.
*1 [Area] can be set for Monitoring 1 and Monitoring 3.
*2 [Point] cannot be set for more than one monitoring system.
*3 [Time to peak] cannot be set for more than one monitoring system.
Summary of Contents for MPC-201-25
Page 1: ...Molding Pressure Conversion Module MPC 201 25 Instruction Manual EN294 1697G ...
Page 2: ......
Page 14: ...XII ...
Page 18: ...XVI 24 4 Vertically positioning the ejector plate 102 24 5 Removing a sensor 103 ...
Page 33: ...15 3 Right click to display the context menu and select Properties ...
Page 34: ...16 4 Click on Update Driver in the Driver tab 5 Select Browse my computer for driver software ...
Page 43: ...25 5 Overlay screen 6 Trend Peak Pressure screen 7 Trend Integral screen ...
Page 122: ......
Page 123: ......